Hearth and Home Technologies Universal Remote SMART BATT II User Manual |
SMART-BATT-II Remote Control Kits
- Installation and Operating Instructions -
CE REQUIREMENTS
INTRODUCTION
The remote control system can be operated thermostati-
cally or manually from the transmitter. The system oper-
ates on radio frequencies (RF) within a 20 foot range. Can
be used with IPI or Standing Pilot systems.
WARNING: CHANGES OR MODIFICATIONS TO
THIS UNIT NOT EXPRESSLY APPROVED BY THE
PARTY RESPONSIBLE FOR COMPLIANCE COULD
VOID THE USER'SAUTHORITY TO OPERATE THE
EQUIPMENT.
This remote control kit has a hand held transmitter that can
be used as a remote on/off or as a thermostat. The trans-
mitter display shows the current room temperature, target
temperature, timer setting, on/off status, low battery indi-
cator, current time and burner/valve operation.
NOTE: This equipment has been tested and found to com-
CE. The operator is required to do as this manual says
ply with
sothatitwillworkverysmart. These limits are designed to
provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause
harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more
of the following measures:
If pertinent, see additional fireplace wiring diagrams on the
following pages.
INSTALLATION PRECAUTIONS
This remote control kit is tested and safe when installed in
accordance with this installation manual. Installation of this
kit MUST be done by a qualified service technician. It is the
responsibility of the installer to read all instructions before
starting installation and to follow these instructions care-
fully during installation. Modification of the remote control
system or any of its components will void the warranty and
may cause a fire hazard.
-
-
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and re-
ceiver.
-
-
Connect the equipment into an outlet on a circuit differ-
ent from that to which the receiver is connected.
CAUTION: ALL Wiring should be done by a qualified electrician
Consult the dealer or an experienced radio TV techni-
cian for help.
and shall be in compliance with CE.
WARNING:DO NO CONNECT 230 VAC WIRING TO THE
GAS CONTROL VALVE OF THIS APPLIANCE.
Printed in China Copyright 2006,
Hearth & Home Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 5504
100-909G 12/06
1
MALE
FEMALE
MALE
RED
BROWN
FEMALE
REMOTE
RECEIVER
BOX
VALVE
ON/OFF
REMOTE SWITCH
Figure 4. Millivolt with Rocker Switch and Receiver
If your fireplace is wired like Figure 3 find the leads on back of the switch marked “For use with remote or wall switch only” and
take the leads and plug them into wire lead on remote receiver box (see Figure 4).
B. Wiring Millivolt Valve with 3-Wire Assembly
3-WIRE ASSEMBLY
PILOT
PIEZO
THERMOCOUPLE
WHITE
RED
VALVE
Figure 5. Millivolt with 3 Wire
If your fireplace is wired like Figure 5 remove 3 wires from the valve by unplugging the spade from the valve. Install the jumper
wire on the terminal on the valve as shown in Figure 6. Then install one of the leads from the receiver onto the valve and the
other wire onto the lead from the jumper wire.
3
REMOTE RECEIVER
PIEZO
PILOT
THERMOCOUPLE
WIRE
TERMINALS
WHITE
LEARN
RED
ON/OFF REMOTE SWITCH
VALVE
Figure 6. Millivolt with Receiver
C. Wiring Intermittent Pilot Ignition (IPI) with Rocker Switch
INTERMITTENT
PILOT
IGNITOR
I
IGNITION MODULE
3 VAC
S
BLACK WIRE CAN BE
PLUGGED INTO ANY OF
#1 - #5 LOCATIONS
WHT
ORG
ON THE HOT SIDE
GROUND TO
FIREPLACE
CHASSIS
WHITE WIRE CAN BE
PLUGGED INTO ANY
OF #1-#5 LOCATIONS
ON THE NEUTRAL SIDE
TRANSFORMER
3 VAC
VALVE
PLUG IN
PIGGYBACK
ON/OFF SWITCH
Figure 7.
Intermittent Pilot Ignition (IPI) Wiring Diagram
4
If your fireplace look like Figure 7 find the leads on the back of switch marked “For use with remote or wall switch only”.
Take the leads and plus them into wire leads on remote receiver box (see Figure 8).
I
INTERMITTENT
REMOTE
RECEIVER
PILOT
IGNITOR
S
IGNITION
MODULE
3 VAC
ON/OFF
SLIDE
SWITCH
N F A
WIRE
TERMINAL
X U A / M R E
TRANSFORMER
WHITE
3 VAC
S
R T A N
ORANGE
GROUND TO
FIREPLACE CHASSIS
PLUG IN
BATTERY PACK
For use with
remote or
VALVE
wall switch only
BLACK
RED
3
1 2
PIGGYBACK
ON/OFF SWITCH
Figure 8.
Intermittent Pilot Ignition (IPI) Wiring Diagram
5
D. Wiring Intermittent Pilot Ignition (IPI) with 3-Wire Assembly
INTERMITTENT
PILOT IGNITOR
IGNITION
MODULE 3 VAC
N
F A
I
X
A / U M R E
S
TRANSFORMER
3 VAC
S N A T R
PLUG IN
WHITE
BATTERY PACK
ORANGE
BLACK
RED
GROUND TO
FIREPLACE CHASSIS
THERMOSTAT
WIRE ASSEMBLY
JUMPER WIRE
(TO BROWN)
Figure 9.
VALVE
If your fireplace looks like Figure 9 remove the 3-wire off the jumper wire by unplugging the spade from jumper wire. Install the
jumper wire on the wire as shown see Figure 10. Then install one of the leads from the remote receiver onto the valve and other
wire into the lead on the jumper wire.
I
INTERMITTENT
PILOT
IGNITOR
ON/OFF
SWITCH
S
IGNITION
MODULE
3 VAC
REMOTE
RECEIVER
N
F A
M
X U A /
R E
TRANSFORMER
3 VAC
S N A T R
WHITE
ORANGE
GROUND TO
FIREPLACE CHASSIS
PLUG IN
JUMPER
WIRE
(TO BROWN)
BATTERY PACK
VALVE
Figure 10.
6
NOTE: The remote receiver houses the microprocessor that
responds to commands from the transmitter to control sys-
tem operation. It emits one beep when it receives an ON or
OFF command manually, but no beep when cycling on and
off automatically in THERMO mode.
TRANSMITTER
Important: Before operating remote control, transmit-
ter and receiver must have matching security codes.
See section ‘Matching Security Codes’.
The remote receiver has a 3-position slide switch: OFF/RE-
MOTE/ON (see Figure 11).
Important: Review ‘Thermo-Safety/Communication-Safety
Features’ under ‘Transmitter Safety Features’ section. These
signal/temperature safety features shut down the fireplace
system when a potentially unsafe condition exists.
WIRE
TERMINALS
BATTERY
COVER
Important: Review ‘Auto Shutdown’ section. This safety
feature shuts down the fireplace after 9 hours of continuous
operation, in ON mode only.
Important: New batteries are essential for proper opera-
tion of the multi-function transmitter. The transmitter oper-
ates on 2 AAA-size 1.5V batteries. Use Alkaline batteries
for longer battery life and maximum operational performance.
Insert 2 AAA-size 1.5V batteries into the battery compart-
ment on the back of the transmitter. When the batteries are
correctly inserted, the screen will display numbers (see
Figure 7 for LCD Display Screen).
LEARNING BUTTON
NOTE: If the transmitter is activated from a very cold condi-
tion it may be necessary to allow the transmitter to stabi-
lize to room temperature (could take up to 15 minutes) be-
fore accurate room temperatures are displayed on the
screen.
ON/OFF REMOTE SLIDE SWITCH
Figure 11. Remote Receiver Slide Switch
NOTE: The remote receiver will only respond to the
transmitter when the 3-position slide button on the re-
mote receiver is in the Remote position. If the system
does not respond to the transmitter on initial use, see
section Matching Security Codes.
NOTE: LCD screen is equipped with a “backlite” for easier
viewing of LCD screen. Backlite illuminates when a func-
tion button is depressed. After 5 seconds elapses, LCD
screen will return to its normal state.
1. With the slide switch in the ON position, the system is
on.
2. With the slide switch in the REMOTE position, the sys-
tem only operates if the remote receiver receives com-
mands from the transmitter.
3. With the slide switch in the OFF position, the system is
off.
NOTE: The slide switch should be placed in the OFF posi-
tion if you will be away from your home for an extended
period of time. Placing the switch in the OFF position also
functions as a safety “lock out” by turning the system off
and rendering the remote receiver inoperative.
7
1. LOW - Battery power low. Replace batteries within two weeks.
2. TIMER - Indicates time remaining before system shuts off, when timer-programmed,
9 - hour maximum setting.
3. MODE - Indicates operation MODE of system. ON indicates the system is on, either
manually or thermostatically. THERMO indicates the system will automatically cycle
ON/OFF, depending on programmed SET temperature. OFF indicates the entire
system is turned off.
LCD DISPLAY SCREEN
4. SET - Indicates desired SET room temperature for
THERMO operation.
ON
THERMO
MODE
3
OFF
1
5. FLAME - Indicates burner/valve operational.
4
ꢀꢂ
7
6
ꢀꢁ F
6. CLOCK - Indicates the current time in AM/PM.
7. ROOM - Indicates CURRENT room temperature.
F
SET
ROOM
SET
UP
8
2
AM
ꢅꢄꢂꢂ
TIMER
TIME
DOWN
O
ꢃꢄꢂꢂ
8. F - Indicates degrees Fahrenheit (0C indicates de-
TIMER
grees Celsius).
5
FLAME
Figure 12. Transmitter LCD Display Screen
MATCHING SECURITY CODES
Transmitter Settings
It may be necessary to program the remote receiver to the
security code of the transmitter upon initial use, if batteries
are replaced, or if a replacement transmitter is purchased
from your dealer. To program the remote receiver:
Flip open the plastic cover on the front of the transmitter to
expose the “SET” buttons.
NOTE: Flashing numbers on the display indicate the sys-
tem is waiting for input, such as using the UP and DOWN
buttons to program a new setting. If no change is made to
flashing digits within 15 seconds, the system will complete
the procedure last programmed and reset the display to its
normal state.
1. Set the slide button on the receiver to the REMOTE
position.
2. Push the LEARN button (one beep will be heard) on the
top of the remote receiver.
3. Then press the MODE button on the transmitter. Sev-
eral beeps indicate the transmitter’s code has been pro-
grammed into the receiver. When an existing receiver is
matched to a new transmitter, the new security code
will overwrite the old one. NOTE: When the LEARN but-
ton is depressed, “beeping” sounds should be heard.
Setting the Clock
1. Press and hold the TIMER/TIME button on the transmit-
ter for more than two seconds. The hour digit(s) will be-
gin flashing (see Figure 12, Location #6).
If you are unsuccessful in matching the security code on
the first attempt, wait 1-2 minutes before trying again.
2. Press the UP or DOWN button until the desired hour is
displayed in AM or PM.
3. After setting the desired hour, press and release the
TIMER/TIME button again to set the minutes; the minute
digits will begin flashing.
OPERATING INSTRUCTIONS
To operate the system, press the MODE button (Figure
12) on the transmitter to select the operational MODE de-
sired.
4. Press the UP or DOWN button until the desired minutes
are displayed.
5. Press and hold the TIMER/TIME button again for more
than two seconds. The time digits will cease flashing,
indicating the clock has been successfully set. You may
also press the SET button on the transmitter to stop the
time digits from flashing and set the time.
• ON indicates the system is on, either manually, timed or
thermostatically.
• THERMO indicates the system will automatically cycle
ON/OFF, depending on programmed set temperature.
• OFF indicates the entire system is turned off.
8
1. Press the MODE button to place the transmitter into
THERMO mode. THERMO ON or OFF will display.
2. Press the UP or DOWN button to select the desired
room temperature. The highest SET temperature is 990
F (320 C). The lowest SET temperature is 450 F (60 C).
ON
78F
NOTE: To prevent repeated thermo-cycling of the gas appli-
ance, the sensing unit in the transmitter will only activate
the remote receiver when the temperature change exceeds
20 F (10 C) above or below the SET (desired) temperature.
ROOM
AM
SETTING
BUTTON
:
800
When the transmitter is in the THERMO mode, it should be
kept away from direct sources of heat such as fireplaces,
incandescent lighting and direct sunlight. Leaving the trans-
mitter in direct sunlight, for example, will cause it to read
the room temperature higher than it actually is.
FLAME
CP
Setting the Countdown Timer
This remote control system can operate with a built-in count-
down timer when the transmitter is in the ON or THERMO
modes (THERMO or ON must be displayed on the LCD
screen).
1. Press and release the TIMER/TIME button on the trans-
mitter. The word TIMER and 0:15 flash on the screen
(see Figure 12, Location #2).
Figure 13. Setting Button/Child Proof Lockout
2. Press the UP and DOWN button to begin advancing
through each of the countdown time options. Available
countdown times are 15 min, 30 min, 45 min, 1 hour, 1
hr 30 min, and each additional half hour up to nine hours.
Setting 0F/0C Scale
The factory setting for temperature is degrees Fahrenheit(0F).
To change this setting to degrees Centigrade (0C):
3. To set the TIMER, press the SET button on the trans-
mitter. If the system is ON, it will remain on until the
“time” has expired. If the system is in the THERMO mode,
it will cycle on and off as the room temperature requires
until the “time” has expired.
1. Remove the battery cover on the back of the transmitter
and locate the “setting button” at the top center of bat-
tery compartment (see Figure 13).
0
2. Push setting button and F will begin flashing on the
NOTE: When the timer is used in the THERMO mode, the
THERMO operation will discontinue when the “time” has
expired.
LCD screen (see Figure 12, Location #4).
3. Push the DOWN button on the transmitter to change 0F
to 0C.
Transmitter Low/Battery Indicator
4. Push “setting button” on transmitter and Centigrade (0C)
degree readings will display on LCD screen.
5. Repeat this process to change back to Fahrenheit (0F)
reading, this time pushing the UP button. NOTE: LCD
screen will return to normal state if setting button is not
pushed within 15 seconds.
An “X” outlined by a battery on the right side of the LCD
screen will appear when battery power has dropped signifi-
cantly. At this time, approximately two weeks of battery
power remains.
Receiver Batteries
The batteries must be replace once every season. It is rec-
ommended to replace at the beginning of the burn season
with 4AA alkaline batteries.
Setting Desired Room Temperature -
Thermo Operations
This remote control system can be thermostatically con-
trolled when the transmitter is in the THERMO mode.
(THERMO must be displayed on the screen). The transmit-
ter will “sense” the room temperature every two minutes
automatically turning the fireplace ON or OFF thermostati-
cally. To set the desired room temperature:
9
Child Proof Lockout (CP)
overridden and the system will return to normal operation
depending on the MODE selected at the transmitter.
The transmitter contains a “Child Proof” lockout feature that
prevents unauthorized use of the remote control. To access
the “Child Proof” activation button, remove cover on BACK of
transmitter. To activate LOCKOUT:
We recommend the user check the batteries in the TRANS-
MITTER to make sure the voltage is no less than 2.7 volts.
Auto Shutdown
1. Press and hold in the “setting button” for 5 seconds.
The letters CP will display on the LCD screen (see Fig-
ure 13). This prevents the activation of fireplace. When
any function button is pressed ON/OFF etc. the letter
CP will display on the LCD screen.
This remote control has anAuto Shutdown feature incorpo-
rated into its system. When the transmitter MODE is in the
ON position the fireplace will continuously operate for 9 hours.
After 9 hours, the fireplace will shut down. To relight the
fireplace:
To deactivate LOCKOUT:
1. Press and hold in the “setting button” for 5 seconds.
The LCD will display CP until 5 seconds have elapsed,
and then the LCD screen will return to its normal state.
1. Press the MODE button.
The transmitter must be positioned within a 20 foot operat-
ing range for theAuto Shutdown feature to operate.
SYSTEM CHECK
Millivolt Valves
TRANSMITTER SAFETY FEATURES
It is recommended that the TRANSMITTERS always be lo-
cated within a 20 foot operating range of the fireplace, pref-
erably in the same room in which the fireplace system is
located. The TRANSMITTER features several safety features
that alert the user when the TRANSMITTER is placed out-
side the 20 foot normal operating range.
Light the appliance following the lighting instructions that
came with the fireplace. Confirm that the pilot flame is on. It
must be in operation for the main gas valve to operate.
1. Slide the 3-position button on the remote receiver to the
ON position. The main gas flame (i.e., the fire) should
ignite.
Thermo-Safety and Communication-Safety Features
This remote control has both a THERMO-SAFETY and
COMMUNICATION-SAFETY function built into its software.
It provides an extra margin of safety when the TRANSMIT-
TER is out of the normal 20 foot operating range of the re-
ceiver. It is also activated when the batteries become weak
or are removed from the transmitter.
2. Slide the button to OFF. The flame should extinguish (the
pilot flame will remain on).
3. Slide the button to REMOTE (the center position), then
press the MODE button on the transmitter to change the
system to ON. The main gas flame should ignite.
4. Press the MODE button on the transmitter to change the
system to OFF. The flame should extinguish (the pilot
flame will remain on).
In the THERMO-SAFETY feature (only in the THERMO or
TIMER modes) the transmitter normally reads the ROOM
temperature every 2 minutes. In addition to checking the
temperature, the transmitter sends a signal to the receiver
indicating that the transmitter and its batteries are still ac-
tive.
5. Press the MODE button on the transmitter to change the
system to THERMO.
6. Advance the SET temperature on the transmitter to a
temperature of at least 20 F (10 C) above the ROOM tem-
perature displayed on the LCD screen and the system
flame will ignite.
7. Set the SET temperature to at least 20 F (10 C) below the
room temperature and the system flame will extinguish.
Thereafter, it should continue to cycle on and off thermo-
statically approximately every two minutes as the ROOM
temperature changes, but only when the temperature dif-
ferential between ROOM and SET temperatures differs
at least 20 F (10 C). The 20 F differential is the factory set-
ting.
In the COMMUNICATION-SAFETY feature, at all times and
in all OPERATING MODES the transmitter sends a signal
every fifteen (15) minutes to the receiver, indicating that the
transmitter is within the normal operating range of 20 feet.
Should the receiver NOT receive a transmitter signal every 2
minutes (THERMO-SAFETY feature) or 15 minutes (COMMU-
NICATION-SAFETY feature), the RECEIVER will begin a 2
HOUR (120 minute) countdown timing function. If during this 2
hour period, the receiver does not receive a signal from the
transmitter, the RECEIVER will shut down the fireplace being
controlled by the receiver. The RECEIVER will then emit a se-
ries of rapid “beeps”. Then, after 10 rapid “beeps”, the RE-
CEIVER will continue to emit a single “beep” every 4 seconds
until a transmitter signal is again received. The intermittent 4
second beeping will go on indefinitely until reset.
Electronic Ignition System
1. Slide the 3-position button on the remote receiver to the
ON position. The spark electrode should begin sparking
to ignite the pilot (the pilot may ignite after only one spark).
After the pilot flame is lit, the main gas valve should open
and the main gas flame should ignite.
To “reset” the RECEIVER and operate the fireplace system:
1. Press the MODE button on the transmitter. The word
ON must display on the LCD screen. The THERMO-
SAFETY and COMMUNICATION -SAFETY operation is
2. Slide the button to OFF. The main gas flame and pilot
flame should BOTH extinguish.
3. Slide the button to REMOTE (the center position).
10
4. Then press the MODE button on the transmitter to change
the system to ON. The spark electrode should begin
sparking to ignite the pilot. After the pilot is lit, the main
gas valve should open and the main gas flame should
ignite.
GENERAL INFORMATION
Transmitter Wall Bracket
The transmitter can be hung on a wall using the bracket
provided. Locate the bracket on an inside wall sufficiently
far away from direct sources of heat such as a fireplace,
incandescent lighting, or sunlight so it detects ambient room
temperatures, not a single heat source. If the bracket is
installed on a solid wood wall, drill 1/8 inch pilot holes and
install with the screws provided. If it is installed on a plas-
ter/wallboard wall, first drill two 1/4 inch holes into the wall,
then use a hammer to tap in the two plastic wall anchors
flush with the wall, then install the screws provided.
5. Press the MODE button on the transmitter to OFF. The
main gas flame and pilot flame should BOTH extinguish.
6. Press the MODE button on the transmitter to change
the system to THERMO.
7. Advance the SET temperature on the transmitter to tem-
perature of at least 20 F (10 C) above the room tempera-
ture displayed on the LCD screen and the system flame
will ignite.
Transmitter Battery Life
Life expectancy of the alkaline batteries in the transmitter
should be at least one season. Check batteries annually.
When the transmitter no longer operates the remote receiver
from a distance it did previously (i.e., the transmitter’s range
has decreased) the batteries should be checked.
8. Set the SET temperature to at least 20 F (10 C) below the
room temperature and the system will extinguish. There-
after, it should continue to cycle on and off thermostati-
cally approximately every two minutes as the ROOM tem-
perature changes, but only when the temperature differ-
ential between ROOM and SET temperatures differ at
least 20 F (10 C). The 20 F differential is the factory setting.
Receiver Batteries
Life expectancy of the alkaline batteries in the receiver one
burn season. Replace with 4AA alkaline batteries at the
beginning of each burn season.
Timer Operation
The countdown timer will operate in either the manual ON or
THERMO mode. Once the fireplace system is in an operat-
ing mode, set the countdown timer to turn off in 15 minutes.
The timer function will allow operation to continue until the
“countdown time” on the LCD screen expires.After 15 min-
utes elapses, the system should turn off.
11
•
•
Cause the RF signal to get lost and not communi-
cate with the receiver.
Troubleshooting
To check the operation of the remote:
1. Make sure receiver batteries are installed properly. If one
battery is installed backward, receiver will not operate in
remote mode. Be sure battery output is 5.3 volts or more.
(Slide switch is independent of battery condition).
Cause the working distance to be shorter than nor-
mal.
NOTE:Areceiver located in an area, where the ambient
temperature inside the case exceeds 1300 F, will cause
the THERMO-SAFETY feature to cut in, requiring you to
reposition the receiver to stop the warning beeps, and to
“reset” the receiver’s operation.
2. Be sure the transmitter’s batteries are properly installed
and that the battery output is 2.7V or more.
3. Check to make sure the transmitter is communicating
with the receiver.
Specifications
• If the receiver beeps when the MODE button is de-
pressed on the transmitter they are communicating.
Batteries: Transmitter - 3V 2 ea.; AAA 1.5V, Alkaline
Receiver: (4) AA I-SV Alkaline
Operating Frequency:
433.92MHZ
• If the receiver does not beep when the MODE button
is depressed on the transmitter go to Matching Secu-
rity Codes.
4. Make sure the transmitter is within the 20 feet range of
the receiver.
5. Positioning of the receiver is important. If the receiver is
“enclosed” in a metal surround, the operation of the re-
ceiver may be affected as noted below. Reposition the
receiver to improve operating range. It is suggested that
a heat shield be installed to protect the receiver from
extreme heat. If the receiver is “enclosed” in a metal
surround, this can:
Service Parts
No service parts available.
Limited Warranty
This REMOTE CONTROL SYSTEM is warranted for
12 months from the date of purchase or installation to
the original purchaser to be free from defects in mate-
rials and workmanship. Damage to the SYSTEM
caused by accident, misuse, abuse, or installation
error whether performed by a contractor, service com-
pany, or owner, is not covered by this warranty. Seller
will not be responsible for labor charges and/or dam-
age incurred in installation, repair, replacement or for
incidental or consequential damages. Batteries and
any damage caused by them are not covered by this
warranty.
Some states, provinces, and nations do not allow
exclusion or limitations of incidental or consequen-
tial damages, so the above limitations or exclusions
may not apply. This warranty gives you specific legal
rights. You may have other rights that vary by state,
province or nation.
12
|