ADTRAN Total Access 750 User Manual

Section 61175043L2-5A  
Issue 1, June 2000  
CLEI Code # SIMPAADA _ _  
Total Access750/850  
AC/DC Power Supply and Battery Charger  
Installation and Maintenance  
Contents  
1. GENERAL ................................................................... 1  
2. DESCRIPTION ............................................................ 1  
3. INSTALLATION.......................................................... 2  
4. SPECIFICATIONS....................................................... 4  
5. MAINTENANCE......................................................... 4  
6. WARRANTY AND CUSTOMER SERVICE .............. 4  
GRN - OK  
YEL - FAIL  
RED - FAIL  
OFF - FAIL  
GRN - OK  
YEL - DISCHARGING  
RED - LOW  
1175043L2  
OFF - NOT CONNECTED  
AC  
BAT  
9902271  
Figures  
Figure 1. TA 750/850 PS/BC, Front and Back ................... 1  
Figure 2. AC/DC Power Supply Battery Charger Layout .. 3  
Figure 3. Alternate Mounting Arrangements ...................... 3  
120 VAC/  
2A 60HZ INPUT  
-54V  
,
2A OUTPUT  
1175043L2  
THIS UNIT MAY BE  
POWERED BY 2  
SOURCES. DI
BOTH S
S
-48V  
,
AC ALARM  
OUTPUT  
Tables  
2A INPUT  
Table 1. Alarm Relay Operation ........................................ 2  
Table 2. LED Indication .................................................... 2  
Table 3. Specifications....................................................... 4  
SE  
FU  
3 AMP  
Figure 1. TA 750/850 PS/BC, Front and Back  
1. GENERAL  
2. DESCRIPTION  
This practice provides installation and maintenance  
procedures for the ADTRANTotal Access 750/850  
Power Supply/Battery Charger. Figure 1 is a front  
and back illustration of the PS/BC.  
The AC/DC Power Supply/Battery Charger provides  
-54 VDC to the Power Supply Unit in the TA 750/850  
Chassis. The PS/BC receives 115 VAC through a  
standard plug and wall socket. The unit works in  
conjunction with an optional ADTRAN backup  
battery pack, P/N 1175044L1, L2, L3. In this  
arrangement, the PS/BC maintains the battery at peak  
charge of -54V. If AC power is lost, the unit  
automatically transfers power from the battery pack  
without interrupting service. When AC power returns,  
the unit switches back to AC power and recharges the  
battery to peak charge.  
Revision History  
This is the initial release of this document. Future  
revisions will be made in this subsection.  
Features  
The Total Access 750/850 PS/BC, P/N 1175043L2,  
features include the following:  
Compact design.  
Versatile mounting arrangements.  
All mounting hardware included.  
Built-in Fuse.  
This device complies with Part 15 of the FCC rules.  
Operation is subject to the following two conditions:  
(1) This device may not cause harmful interference,  
and (2), this device must accept any interference that  
may cause undesired operation.  
Multi-feature status LED.  
Modular connections.  
Positive ground.  
Changes or modifications not expressly approved by  
ADTRAN could void the user’s authority to operate  
this equipment.  
Uninterrupted power output if battery backup  
connected.  
FCC and UL 1950 compliant.  
Trademarks:Anybrandnamesandproductnamesincludedinthisdocumentare  
trademarks, registered trademarks, or trade names of their respective holders.  
61175043L2-5A  
1
There are three installation arrangements:  
Optional Mounting Locations  
Wallmount.  
Mounted to TA 750/850 chassis.  
Mounted to backup Battery Pack (L1 only).  
As an optional installation arrangement, the PS/BC  
unit can mount on either side of the TA 750/850  
chassis, or the top of the battery pack (wall or rack  
orientation) which has space for two PS/BCs. These  
locations all have pre-threaded inserts designed for the  
PS/BC. For installation, four #6-32 by 3/8-inch  
machine screws are provided.  
Wallmounting  
For the wallmount arrangement, the PS/BC is  
normally installed on the designated 3/4-inch or  
thicker plywood with four #6 by 3/4-inch  
flat-head wood screws.  
CAUTION  
Refer to Figure 2. Installation is as follows:  
When mounting to the battery pack, using  
screws longer than 3/8-inch could damage  
batteries.  
1. Determine the preferred layout and ensure the  
socket-outlet is located near the equipment and  
easily accessible.  
2. Ensure the unit is plumb then mark through the  
four screw holes to identify where the pilot  
holes will be drilled.  
3. Using a 1/16-inch bit, drill pilot holes at the  
marked locations.  
4. Mount the unit using the pan-head screws.  
5. Route and connect all cabling to the appropriate  
device. Use cable tie-downs as needed.  
6. Connect the ground stud using the most direct  
route to a known equipment ground source.  
-48 VDC Backup Battery Pack  
TA 750  
V.35  
WARNING:  
20 Hz FUSE  
MUST BE REMOVED  
BEFORE REMOVING COVER.  
Terminal  
T1  
access
cover  
FT1  
1175044L1  
BATTERY BACKUP  
MANAGEMENT  
DC  
POWER  
WARNING:  
SCREW LENGTHS EXCEEDING 3/8"  
MAY PUNCTURE BATTERIES  
To Alarms  
CAUTION  
During TA 750 wall installation,  
position the chassis so  
front panels face up.  
-54 VDC Output to TA 750  
120  
V
A
C/  
-
54V  
,
2A 60HZ  
I
NPUT  
2A OUTPUT  
TH  
I
S
U
NI  
T
M
A
Y
BE  
2
POWERED BY  
SOURCES. DISCONNECT  
BOTH SOURCES BEFORE  
AC/DC Power Supply  
-
48V  
,
A
C
A
LARM  
SERV CING.  
I
2A NPUT  
I
OUTPUT  
Battery Charging Unit  
P/N: 1175043L2  
3
AMP  
-54 VDC Battery  
Charging/Discharging Line  
AC Power Input  
Figure 2. AC/DC Power Supply Battery Charger Layout  
61175043L2-5A  
Section 61175043L2-5, Issue 1  
3
Refer to Figure 3 for optional mounting arragements.  
Table 3. Specifications  
Electrical  
AC Input: 115 Volts nominal  
Range: 88 to 132 VAC  
ON  
DC Output: -54 Volts, 60 Watts average  
100 Watts peak  
OF  
2
A
M
P
2AMP  
W
GRN-OK  
    D
T
RED-LO  
          G
BA  
75043L1  
F-NO  
IL  
A
IL  
A
IL  
A
GRN-OK  
YEL-F  
RED-F  
 -
AC  
Battery charging: 16 hr nominal, 24 hr maximum  
Battery discharge: Up to 8 hours  
Physical  
AC  
O-F  
RDE-F  
YLE-F  
GNR-OK  
A
I
A
I
A
L
Dimensions: 3 1/2" W x 1 3/4" H x 7" L  
(including mounting tabs)  
F-NO  
B
70543L1  
YLE-DSCHARING  
T
RDE-LO  
OCNTED  
GNR-OK  
W
2AMP  
P
M
A
2
OF  
ON  
Weight: 1 lb. 8 Oz.  
Environmental  
N
O
2
A
M
P
Operating temperature: 0º to 50º C (32º to 122º F)  
Storage temperature: -40º to 85º C (-40º to 185º F)  
Relative humidity: 95% non-condensing  
F
F
1
O
L
3
4
0
5
7
K
R
1
O
G
1
-
I
N
N
G
R
A
G
H
L
P
M
C
I
S
W
D
D
O
E
A
-
C
T
E
L
D
C
T
-
N
E
2
Y
E
N
R
O
K
L
L
O
I
A
AI  
O
-
N
N
-
R
G
F
F
F
O
E
L
-
-
-
Y
F
T
E
D
AI  
L
A
B
R
F
F
F
O
C
A
N
O
2
A
M
P
F
F
1
O
L
3
4
0
5
7
K
R
1
G
1
-
I
N
N
G
R
A
G
P
M
C
I
S
D
D
O
T
A
-
2
E
L
D
-
E
Y
E
R
N
K
L
L
O
T
C
-
N
O
N
I
R
A
G
F
F
F
-
O
E
L
-
-
-
AI  
Y
F
T
E
D
AI  
L
R
F
F
F
O
C
B
A
years from the date of shipment if it does not meet its  
published specifications or fails while in service  
(see: ADTRAN Equipment Warranty, Repair, and  
Return Policy and Procedure, document:  
60000087-10A).  
Contact Customer And Product Service (CAPS) prior  
to returning equipment to ADTRAN.  
For service, CAPS requests, or further information,  
contact one of the following numbers:  
Figure 3. Alternate Mounting Arrangements  
Grounding  
The ground connector on the PS/BC provides an  
additional ground reference (the third prong of the  
AC plug is also grounded) and may be connected to  
“ground bus” or “ground wire” in a customer  
equipment room. 18 AWG or larger ground wire is  
recommended.  
ADTRAN Sales  
Pricing and availability  
(888) 4-ADTRAN  
ADTRAN Technical Support  
Presales Applications / Post-sale Technical Assistance  
(800) 726-8663  
Standard support hours:  
4. SPECIFICATIONS  
Monday-Friday, 7 a.m. - 7 p.m. CST  
Refer to Table 3 for specifications.  
Emergency support: 7 days/week, 24 hours/day  
5. MAINTENANCE  
The AC/DC Power Supply/Battery Charger does not  
require routine maintenance for design operation.  
ADTRAN Repair/CAPS  
Return for repair / upgrade  
(256) 963-8722  
ADTRAN does not recommend that repairs be  
attempted in the field. Repair services are obtained by  
returning the defective unit to ADTRAN Customer  
Service.  
Repair and Return Address:  
ADTRAN, Inc.  
Customer and Product Support (CAPS)  
901 Explorer Boulevard  
6. WARRANTY AND CUSTOMER SERVICE  
ADTRAN will replace or repair this product within 10  
Huntsville, Alabama 35806-2807  
4
Section 61175043L2-5, Issue 1  
61175043L2-5A  

AllerAir 4000 Exec User Manual
Compaq A4000 User Manual
Energizer IEC LR43 User Manual
Friedrich HA18K User Manual
Friedrich SQ05N10 User Manual
Haier HSU 22LE03 User Manual
Honda Automobiles Automobile Parts GXV610 User Manual
Honeywell s HercuLine 2000 User Manual
HP Hewlett Packard DESKJET 2050 User Manual
Human Touch Automobile Accessories HT 100 User Manual