AllerAir 6000 User Manual

The 4000 - 5000 - 6000 - 8000 Series - Air Purifier  
Congratulations, you are moments away from fresher, cleaner indoor air. Your new  
AllerAir unit will combat many of the chemicals, gases, odors and particles  
responsible for poor indoor air quality, and in turn, health concerns such as  
allergies, asthma, sick building syndrome and multiple chemical sensitivity. As with  
any air cleaner, proper maintenance of your unit is a vital part of keeping it  
operating at peak efficiency.  
Operation:  
Your unit is shipped fully assembled and ready for use. Plug into 120V-15amp  
outlet. For best results situate your unit close to your sitting, sleeping or work area.  
NOTE: Please save your packaging. Original packaging will be required for all  
warranty returns.  
Operation and Maintenance Manual  
FIVE YEAR (5) LIMITED WARRANT  
ALLERAIR  
Warrants their home use 4, 5, 6 & 8000 series units to be free from defects in  
materials and workmanship under normal use and service for a period of 5 years  
from date of purchase.  
The obligation of this warranty shall be limited to repairing or replacing any part  
of the unit which we agree is defective in materials or workmanship under normal  
use and service during the five year period commencing with the date of  
purchase, sent with the original or sufficient packaging protection.  
Please call toll free 1-888-852-8247 for detailed return instructions.  
This five year warranty is in lieu of all other express warranties, obligations or  
liabilities (expect those implied warranties, which in some states cannot be  
excluded).  
No agent, representative, dealer or employee of the company has the authority to  
increase or alter the obligations of this warranty. This warranty shall not apply to  
any unit which has been modified, repaired or altered in any way without the  
express written consent of AllerAir Industries Inc. This warranty does not apply to  
any expendable parts of the unit.  
In no case shall AllerAir Industries Inc. be liable for any consequential damages for  
breach of this or any other warranty expressed or implied whatsoever.  
This warranty is limited to the original retail purchaser and is not transferable.  
Kindly address any questions regarding this warrany to AllerAir Industries Inc.  
EXTENDED WARRANTY  
Model #  
Serial #  
AllerAir's five year warranty is extendible to 10 years. Kindly call for information.  
4000 - 5000 - 6000 - 8000 Series  
Air Purifiers  
AllerAir manufactures the most effective air purification systems, using the latest  
technology available today. These are distributed worldwide for commercial,  
residential, institutional and industrial use. The units meet all the higest standards  
required for safety and health.  
1
8
AllerAir Industries Inc.  
Toll free: 1-888-852-8247 / Fax: 1-877-688-2193 www.allerair.com  
AllerAir Industries Inc. Toll free: 1-888-852-8247 / Fax: 1-877-688-2193 www.allerair.com  
TO REPLACE THE HEPA FILTER  
TO REPLACE UV BULB AND BALLAST  
7A  
Step 7- 10 W Lamp  
Step 1  
Turn power off  
Lay unit up-side  
down.  
Step 2  
4 pin socket  
With screw driver  
remove 4 screws.  
7B  
STEP 2  
STEP 1  
STEP 3  
Remove all four screws  
with a screwdriver.  
Turn power off and  
Unplug the unit.  
Gently grasp wheels.  
Lay unit up-side down.  
Step 3  
A. Unplug the 4 pin  
socket from the UV light bulb.  
Gently grasp  
wheels.  
Wing Nut  
B. Loosen the wing nut that holds  
the UV light bulb  
in place and remove bulb  
Step 4  
Remove lit by pulling  
slightly on wheels  
7A  
Step 7 - 20W Lamp  
STEP 5  
STEP 6  
STEP 4  
First remove the  
Carbon filter  
Remove the HEPA filter  
by placing thumbs on the  
inner side of the filter  
and grip the filter.  
Remove base  
by gently  
by placing thumbs on  
Nylon wrap  
pulling on  
the wheels.  
the inner side of the filter.  
Then pull up gently  
to remove filter.  
Step 5  
Removing Filters  
Carbon Filters  
To refill the Carbon Canister without changing the HEPA filter  
go to STEP 7 on page 5.  
Remove the filter(s)  
depending on  
your model  
A. Cut the nylon tie wrap  
that was holding the  
UV light bulb in place during  
shipping  
HEPA filter: 3 to 5 years depending on use.  
4 pin socket  
B. Unplug the 4 pin  
socket from the UV light bulb  
HEPA Filter Order Guide  
HEPA Filters  
4000  
A4FH0411  
A4FH0420  
5000  
A5FH0411  
A5FH0420  
6000  
A6FH0411  
A6FH0420  
8000  
A8FH0411  
Models  
Exec, Vocarb  
MCS  
Step 6  
Step 8  
Step 9  
Remove the  
three screws that  
hold in  
Place the new  
After securing the wing nut,  
replace the 4 prong connector  
which only  
*Please use the above part numbers when ordering your replacement parts  
bulb in the  
holder and check that  
the filter end plate the bulb is horizontal  
connects one-way.  
and remove  
and not touching  
anything before  
tightening the nut.  
"Notice the prongs are wider  
one way than the other"  
Notes:  
Replace the filter end plate making sure the aluminium side is down  
toward the side of the bulb.  
Replace the screws, filter(s) and bottom with the 4 screws  
6
3
AllerAir Industries IncT.oll free: 1-888-852-8247 / Fax: 1-877-688-2193 www.allerair.com  
AllerAir Industries Inc. Toll free: 1-888-852-8247 / Fax: 1-877-688-2193 www.allerair.com  
ALLERAIR'S AIR PURIFICATION SYSTEM  
TO BEGIN USING THE AIR PURIFIER  
LASER TESTED TRUE HEPA  
Wipe the unit with a damp cloth.  
Plug the unit into a grounded 110 outlet.  
HEPA (Hight Efficiency Particulate Arrestance) filters were develped for the Atomic  
Energy Commission to remove radio active dust from their laboratories. The are now the  
primary filtration systems for electonic clean room assembly, hospital surgeries, bio  
engineering, pharmaceutical laboratories and any other space where clean air is critical.  
Turn the unit on at  
TURBO and let it run for a moment.  
Place the unit in the desired area and set at HIGH for regular daytime use  
and at LOW for overnight.  
The most effective way to use the air purifier is to run it on low  
HEPA will trap microscopic dust which will give you distress from allergies, asthma,  
respiratory problems, chemical sensitivities and sick building syndrome. It will trap  
99.97% of all particles down to 0.3 microns (including bacteria, dust mite antigens,  
respiratory particles, fungal and other microbiologicals. For these reasons that HEPA  
filtration is recommended by more allergists, medical professionals and clean air  
consultants than any other filter system available.  
TO REPLACE OR CLEAN THE PRE-FILTER  
CARBON FILTER (ACTIVATED AND GRANULATED)  
We use only activated granular carbon mixed with zeolite and specially impregnated  
carbons. We stay away from dust carbon which has been impregnated onto a poly or  
foam material. This type of carbon filter has to be changed as often as every week to be  
fully effective. AllerAir's carbon filter can last up to 2 or 3 years and more, depending on  
the level of toxins in the area.  
The activated carbon we use is derived from coconut shell and can adsorb up to 60% of  
its own weight in toxic gases, fumes and chemicals. These toxic substances make us ill,  
and are found in every home, office and industry.  
STEP C  
STEP B  
STEP A  
Replace the new or cleaned  
pre-filter by gently pressing  
against inner carbon filter.  
Gently return the unit to the  
upright position.  
Remove the pre- filter  
gently to avoid disturbing  
the dust on it.  
Turn off the unit.  
Unplug the unit.  
Gently tilt over the unit.  
OTHER FILTERING SYSTEMS AVAILABLE  
Ozone generators, negative ion machines and electrostatically charged units all  
generate ozone which is a toxic substance. Any unit which provides ozone cannot be  
recommended by Health and Welfare or by the Lung Association.  
Either  
Vacuum the pre-filter  
on both sides and replace.  
Or  
AllerAir's units on the other hand do not produce any ozone whatsoever. The latest air  
purification technology does not add anything to the air (especially impurities like  
ozone or P.V.C.s). AllerAir's unit scrubs impurities and toxins out of the air.  
Place the old pre-filter in a garbage bag  
for disposal.  
ENERGY COSTS  
We use a high efficiency motor which cost pennies a day to operate in contrast to  
almost all other manufactures who use the lowest price motor available. One of the  
reasons we can offer a five year extendible to ten year warranty is because of the  
sophisticated motor we use. We have spared no effort to give you the most for the least.  
Pre-filter : Vacuum every 1 or 2 months. Replace when necessary.  
Warning  
ADDITIONAL INFORMATION  
Before removing the top or bottom off the unit for any reason, unplug the unit.  
The rush of air on "Low", makes less noise which is often used to help people sleep more  
soundly. Use "High" in work places or home living rooms. Use "Turbo" when you are out  
of the area for the day or night. The sound you hear from the unit is the sound of the air  
passing through the vent to achieve a current so that your complete area will receive  
changes of air.  
Do not allow any object to be stuck or paked into any opening of the unit.  
(i.e. louvers or control knob.)  
The air coming out of the unit may feel cool to your hand, but the temperture of the air  
is actually the same. And AllerAir units are specially designed to have no offgasing  
because our entire unit housing is made of steel.  
Prefilters Order Guide*  
4000  
A4FMP006  
5000  
A5FMP009  
6000  
A6FMP012  
8000  
Notes  
Models  
Prefilters  
Poly Prefilters  
IMPORTANT NOTICE  
Exec, Vocarb  
DS Models  
MCS Models  
A8FMP008 packs of 4 or 8  
packs of 10  
To receive maximum use of HEPA filter media when used in freshly painted room, you  
should first remove the HEPA filter from the unit to avoid contaminating the HEPA  
media. Turn unit off and Ungplug unit. Remove bottom screws. Open bottom of unit,  
Grasp outer filter ring firmly with both hands and remove carefully. Close unit, plug into  
grounded receptacle then turn on. Replace carbon filter before reinstalling HEPA filter.  
Tacky Prefilters A4FMPS06 A5FMPS09 A6FMPS12  
Cotton Prefilters A4FCP016 A5FCP019 A6FCP022  
*Please use the above part numbers when ordering your replacement parts  
packs of 6  
Do not allow any object to be stuck or poked into any opening of the unit.  
Never service the unit before turning unit off and removing electrical plug  
from the wall receptacle.  
7
2
AllerAir Industries Inc. Toll free: 1-888-852-8247 / Fax: 1-877-688-2193 www.allerair.com  
AllerAir Industries Inc. Toll free: 1-888-852-8247 / Fax: 1-877-688-2193 www.allerair.com  

Acura 08B21SJA_200081 User Manual
Briggs Stratton 80100 User Manual
Carrier COMFORT 50ES A User Manual
Eveready Battery Charger EV2PC2 User Manual
Extech Instruments Printer MPP II User Manual
GE Zoneline AZ38H12D User Manual
Goodman Mfg Co LP Air Conditioner SS CE120 User Manual
Haier AS092AMNBA User Manual
Haier AU092ACAAA User Manual
Haier Commercial Cool CPN12XH9 User Manual