The 4000 - 5000 - 6000 - 8000 Series - Air Purifier
Congratulations, you are moments away from fresher, cleaner indoor air. Your new
AllerAir unit will combat many of the chemicals, gases, odors and particles
responsible for poor indoor air quality, and in turn, health concerns such as
allergies, asthma, sick building syndrome and multiple chemical sensitivity. As with
any air cleaner, proper maintenance of your unit is a vital part of keeping it
operating at peak efficiency.
Operation:
Your unit is shipped fully assembled and ready for use. Plug into 120V-15amp
outlet. For best results situate your unit close to your sitting, sleeping or work area.
NOTE: Please save your packaging. Original packaging will be required for all
warranty returns.
Operation and Maintenance Manual
FIVE YEAR (5) LIMITED WARRANT
ALLERAIR
Warrants their home use 4, 5, 6 & 8000 series units to be free from defects in
materials and workmanship under normal use and service for a period of 5 years
from date of purchase.
The obligation of this warranty shall be limited to repairing or replacing any part
of the unit which we agree is defective in materials or workmanship under normal
use and service during the five year period commencing with the date of
purchase, sent with the original or sufficient packaging protection.
Please call toll free 1-888-852-8247 for detailed return instructions.
This five year warranty is in lieu of all other express warranties, obligations or
liabilities (expect those implied warranties, which in some states cannot be
excluded).
No agent, representative, dealer or employee of the company has the authority to
increase or alter the obligations of this warranty. This warranty shall not apply to
any unit which has been modified, repaired or altered in any way without the
express written consent of AllerAir Industries Inc. This warranty does not apply to
any expendable parts of the unit.
In no case shall AllerAir Industries Inc. be liable for any consequential damages for
breach of this or any other warranty expressed or implied whatsoever.
This warranty is limited to the original retail purchaser and is not transferable.
Kindly address any questions regarding this warrany to AllerAir Industries Inc.
EXTENDED WARRANTY
Model #
Serial #
AllerAir's five year warranty is extendible to 10 years. Kindly call for information.
4000 - 5000 - 6000 - 8000 Series
Air Purifiers
AllerAir manufactures the most effective air purification systems, using the latest
technology available today. These are distributed worldwide for commercial,
residential, institutional and industrial use. The units meet all the higest standards
required for safety and health.
1
8
AllerAir Industries Inc.
TO REPLACE THE HEPA FILTER
TO REPLACE UV BULB AND BALLAST
7A
Step 7- 10 W Lamp
Step 1
Turn power off
Lay unit up-side
down.
Step 2
4 pin socket
With screw driver
remove 4 screws.
7B
STEP 2
STEP 1
STEP 3
Remove all four screws
with a screwdriver.
Turn power off and
Unplug the unit.
Gently grasp wheels.
Lay unit up-side down.
Step 3
A. Unplug the 4 pin
socket from the UV light bulb.
Gently grasp
wheels.
Wing Nut
B. Loosen the wing nut that holds
the UV light bulb
in place and remove bulb
Step 4
Remove lit by pulling
slightly on wheels
7A
Step 7 - 20W Lamp
STEP 5
STEP 6
STEP 4
First remove the
Carbon filter
Remove the HEPA filter
by placing thumbs on the
inner side of the filter
and grip the filter.
Remove base
by gently
by placing thumbs on
Nylon wrap
pulling on
the wheels.
the inner side of the filter.
Then pull up gently
to remove filter.
Step 5
Removing Filters
Carbon Filters
To refill the Carbon Canister without changing the HEPA filter
go to STEP 7 on page 5.
Remove the filter(s)
depending on
your model
A. Cut the nylon tie wrap
that was holding the
UV light bulb in place during
shipping
HEPA filter: 3 to 5 years depending on use.
4 pin socket
B. Unplug the 4 pin
socket from the UV light bulb
HEPA Filter Order Guide
HEPA Filters
4000
A4FH0411
A4FH0420
5000
A5FH0411
A5FH0420
6000
A6FH0411
A6FH0420
8000
A8FH0411
Models
Exec, Vocarb
MCS
Step 6
Step 8
Step 9
Remove the
three screws that
hold in
Place the new
After securing the wing nut,
replace the 4 prong connector
which only
*Please use the above part numbers when ordering your replacement parts
bulb in the
holder and check that
the filter end plate the bulb is horizontal
connects one-way.
and remove
and not touching
anything before
tightening the nut.
"Notice the prongs are wider
one way than the other"
Notes:
Replace the filter end plate making sure the aluminium side is down
toward the side of the bulb.
Replace the screws, filter(s) and bottom with the 4 screws
6
3
ALLERAIR'S AIR PURIFICATION SYSTEM
TO BEGIN USING THE AIR PURIFIER
LASER TESTED TRUE HEPA
Wipe the unit with a damp cloth.
Plug the unit into a grounded 110 outlet.
HEPA (Hight Efficiency Particulate Arrestance) filters were develped for the Atomic
Energy Commission to remove radio active dust from their laboratories. The are now the
primary filtration systems for electonic clean room assembly, hospital surgeries, bio
engineering, pharmaceutical laboratories and any other space where clean air is critical.
Turn the unit on at
TURBO and let it run for a moment.
Place the unit in the desired area and set at HIGH for regular daytime use
and at LOW for overnight.
The most effective way to use the air purifier is to run it on low
HEPA will trap microscopic dust which will give you distress from allergies, asthma,
respiratory problems, chemical sensitivities and sick building syndrome. It will trap
99.97% of all particles down to 0.3 microns (including bacteria, dust mite antigens,
respiratory particles, fungal and other microbiologicals. For these reasons that HEPA
filtration is recommended by more allergists, medical professionals and clean air
consultants than any other filter system available.
TO REPLACE OR CLEAN THE PRE-FILTER
CARBON FILTER (ACTIVATED AND GRANULATED)
We use only activated granular carbon mixed with zeolite and specially impregnated
carbons. We stay away from dust carbon which has been impregnated onto a poly or
foam material. This type of carbon filter has to be changed as often as every week to be
fully effective. AllerAir's carbon filter can last up to 2 or 3 years and more, depending on
the level of toxins in the area.
The activated carbon we use is derived from coconut shell and can adsorb up to 60% of
its own weight in toxic gases, fumes and chemicals. These toxic substances make us ill,
and are found in every home, office and industry.
STEP C
STEP B
STEP A
Replace the new or cleaned
pre-filter by gently pressing
against inner carbon filter.
Gently return the unit to the
upright position.
Remove the pre- filter
gently to avoid disturbing
the dust on it.
Turn off the unit.
Unplug the unit.
Gently tilt over the unit.
OTHER FILTERING SYSTEMS AVAILABLE
Ozone generators, negative ion machines and electrostatically charged units all
generate ozone which is a toxic substance. Any unit which provides ozone cannot be
recommended by Health and Welfare or by the Lung Association.
Either
Vacuum the pre-filter
on both sides and replace.
Or
AllerAir's units on the other hand do not produce any ozone whatsoever. The latest air
purification technology does not add anything to the air (especially impurities like
ozone or P.V.C.s). AllerAir's unit scrubs impurities and toxins out of the air.
Place the old pre-filter in a garbage bag
for disposal.
ENERGY COSTS
We use a high efficiency motor which cost pennies a day to operate in contrast to
almost all other manufactures who use the lowest price motor available. One of the
reasons we can offer a five year extendible to ten year warranty is because of the
sophisticated motor we use. We have spared no effort to give you the most for the least.
Pre-filter : Vacuum every 1 or 2 months. Replace when necessary.
Warning
ADDITIONAL INFORMATION
Before removing the top or bottom off the unit for any reason, unplug the unit.
The rush of air on "Low", makes less noise which is often used to help people sleep more
soundly. Use "High" in work places or home living rooms. Use "Turbo" when you are out
of the area for the day or night. The sound you hear from the unit is the sound of the air
passing through the vent to achieve a current so that your complete area will receive
changes of air.
Do not allow any object to be stuck or paked into any opening of the unit.
(i.e. louvers or control knob.)
The air coming out of the unit may feel cool to your hand, but the temperture of the air
is actually the same. And AllerAir units are specially designed to have no offgasing
because our entire unit housing is made of steel.
Prefilters Order Guide*
4000
A4FMP006
5000
A5FMP009
6000
A6FMP012
8000
Notes
Models
Prefilters
Poly Prefilters
IMPORTANT NOTICE
Exec, Vocarb
DS Models
MCS Models
A8FMP008 packs of 4 or 8
packs of 10
To receive maximum use of HEPA filter media when used in freshly painted room, you
should first remove the HEPA filter from the unit to avoid contaminating the HEPA
media. Turn unit off and Ungplug unit. Remove bottom screws. Open bottom of unit,
Grasp outer filter ring firmly with both hands and remove carefully. Close unit, plug into
grounded receptacle then turn on. Replace carbon filter before reinstalling HEPA filter.
Tacky Prefilters A4FMPS06 A5FMPS09 A6FMPS12
Cotton Prefilters A4FCP016 A5FCP019 A6FCP022
*Please use the above part numbers when ordering your replacement parts
packs of 6
Do not allow any object to be stuck or poked into any opening of the unit.
Never service the unit before turning unit off and removing electrical plug
from the wall receptacle.
7
2
|