INITIAL SET-UP  
CAUTION: The dispenser is very heavy! Use care when lifting or moving it. Use at least two people to lift or move  
the dispenser. Place dispenser on a sturdy counter or shelf able to support at least 150 lbs. (68 kg). The JDF-2  
is designed for indoor use only.  
Set the dispenser on the counter where it will be used. The JDF-2 requires a minimum of 4 inches (102 mm)  
of air clearance at the rear and 8 inches (203 mm) of air clearance above the dispenser. Minimal clearance is  
requiredbetweenthedispensersidesandthewalloranotherappliance.Foroptimumperformance,donotletwarm  
air from surrounding machines blow on the JDF-2. Leave some space so the dispenser can be moved for cleaning.  
ELECTRICAL REQUIREMENTS  
CAUTION: The dispenser must be disconnected from the power source until specified in Electrical Hook-Up.  
The 120V rated dispensers have an attached cord set and require a 2-wire, grounded, individual branch circuit  
rated 120 volts ac, 15 amp, single phase, 60Hz. The mating connector must be a NEMA 5-15R. (Refer to the data  
plate for exact electrical requirements.)  
The230Vrateddispensershaveanattachedcordthatrequiresanattachmentplugcapratedatleast10a, 230V.  
The attachment plug cap must meet with applicable national/local electrical codes.  
ELECTRICAL HOOK-UP  
CAUTION: Improper electrical installation will damage electronic components.  
1. An electrician must provide electrical service as specified.  
2. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.  
3. Connect the dispenser to the power source.  
4. If plumbing is to be hooked up later, be sure the dispenser is disconnected from the power source. If plumbing  
has been hooked up, the dispenser is ready for Initial Fill.  
PLUMBING REQUIREMENTS  
This dispenser must be connected to a COLD WATER system with operating pressure between 20 and 100 psi  
(138 and 690 kPa). This water source must be capable of producing a minimum flow rate of 3 fluid ounces (88.7  
milliliters) per second. A shut off valve should be installed in the line before the dispenser. Install a regulator in  
the line when pressure is greater than 100 psi (690 kPa) to reduce it to 50 psi (345 kPa). The main water inlet is  
a 3/8” (9.52 mm) MFL connection.  
Additionally, the dispenser’s rinse connection may be connected to a HOT WATER system.  
Caution:  
MAXIMUM RINSE WATER TEMPERATURE: 170 degrees F (76.6 degrees C)  
UseBUNN-O-MATICtubing,partnumber32759.10__(seeIllustratedPartsCatalogforcompletepartnumber)  
for hot water connection.  
The rinse water operating pressure must be between 20 and 100 psi (138 and 690 kPa). A shut off valve should  
be installed in the line before the dispenser. Install a regulator in the line when pressure is greater than 100 psi (690  
kPa) to reduce it to 50 psi (345 kPa). The rinse water inlet is a 1/4" (6.35 mm) MFL connection.  
NOTE- At least 18 inches (457 mm) of an FDA approved flexible beverage tubing, such as reinforced braided  
polyethylene or silicone, before the dispenser will facilitate movement to clean the countertop. It can be pur-  
chased direct from BUNN-O-MATIC (part number 32759.10_ _ [see Illustrated Parts Catalog for complete part  
35303 081503  
4
PLUMBING REQUIREMENTS (cont)  
number.]) BUNN-O-MATIC does not recommend the use of saddle valves to install the dispenser. The size and  
shape of the hole(s) made in the supply line(s) by saddle valves may restrict water flow.  
Note- A water strainer (Bunn-O-Matic part number 23720.1000) should be installed in line, prior to the  
flexible water line. This strainer is supplied loose with the dispenser. (See Fig. 2 for proper locations)  
This equipment must be installed to comply with the Basic Plumbing Code of the Building Officials and  
CodeAdministratorsInternational, Inc. (BOCA)andtheFoodServiceSanitationManualoftheFoodand  
Drug Administration (FDA).  
INITIAL FILL  
CAUTION: The dispenser must be disconnected from the power source throughout the initial fill except when  
specified in the instructions.  
1. Remove drip tray assembly and splash panel from the dispenser.  
2. Pull the overflow tube from its retaining clip and connect it to the main water source (black gasket is supplied  
in install kit).  
3. Slowly open the water shut off valve and fill the water bath until water trickles from the overflow.  
4. Connect dispenser to the power source.  
5. After 3 minutes of power, slowly add more water to the tank until water trickles from overflow again.  
6. Once water bath is filled, remove water source, cap dispenser fill line, and store the fill tube in it’s holder (the  
fill tube can now be used as a sight glass).  
7. Replace the splash panel and drip tray.  
8. Place refrigeration switch to the “ON” position. It will take approximately three hours at 75° F (24° C) ambient  
to create the ice bank required for full dispenser performance. During this time, some further trickling from  
the water bath is expected due to expansion caused by ice bank formation. While the refrigeration system is  
creating the ice bank, the dispenser may be readied for use as described in Plumbing, Loading, Priming and  
Adjustment.  
P2655  
FIG 1 Initial Fill Connection  
35303 081503  
5
PLUMBING HOOKUP  
All plumbing connections are located on the rear of the dispenser. Both the rinse and potable water line must  
be connected to a water source. A water hookup kit is included with each dispenser.  
P2656  
FIG 2 Plumbing Connections  
LOADING  
Frozen Concentrates  
1. Thaw the frozen concentrate in a refrigerated 35-40 degrees F (1.6-4.4 degrees C) environment for 36 to 48  
hours before use.  
2. Thoroughly mix the thawed concentrate by vigorously shaking the product container.  
3. Open the dispenser door.  
4. Prior to placing the product container in the dispenser, make sure that the o-ring on the container adapter is  
lubricated. This will ease removal of the container when it becomes necessary.  
5. Place the product container in the desired position and press it firmly into the bottle adapter opening.  
6. Open the vent hole in the product container.  
Note: Concentrate in the container must be completely thawed and be within the temperature range of 35-40  
degrees F (1.6-4.4 degrees C.) Product outside of this temperature range, especially below, will produce an  
“out of brix” drink.  
Ambient Concentrates (Optional)  
1. InstallanAmbientConcentrateConversionKit(BUNN-O-MATICpartnumber33699.0001)pertheinstructions  
provided in the kit.  
2. Attach the concentrate product hose to the appropriate concentrate line located at the rear of the dispenser.  
3. Attach the other end of the product hose to the product container through an appropriate fitting.  
PRIMING  
1. Open the dispenser door  
2. Load concentrate per instructions in section titled Loading.  
3. Close the dispenser door.  
4. Place a large container under the appropriate dispense nozzle.  
5. Dispensers with Press and Hold Feature:  
PressandholdtheProductDispenseSwitchFig4, untilconcentratedispensesfromthedispensenozzle.  
Dispensers with Portion Control Feature:  
Press and hold the “+/STOP Switch” Fig 5, until concentrate dispenses from the dispense nozzle.  
Note: This may take several seconds, depending on the installation and programmed pump speed.  
35303 012703  
6
OPERATING CONTROLS  
Refrigeration Switch  
The refrigeration switch is located on the top of the dispenser near the  
left rear corner. This switch controls power to the compressor and the  
condenser fan motor.  
P2261  
FIG 3 Refrigeration Switch  
Sanitize Switch  
The sanitize switch is located behind the drip tray in the lower left corner  
of the chassis. The drip tray can be removed to provide easy access to  
theswitch. Thesanitizeswitchisusedtoenterandexitthesanitizemode  
and to initiate the sanitize automatic cycle. Refer to Weekly Sanitizing in  
the Cleaning section for detailed instructions on the use of this switch.  
P2657  
FIG 4 Sanitize Switch  
35303 012703  
7
OPERATING CONTROLS (cont.)  
B
B
A
A
C
FIG 5 Press and Hold Models  
A. Product Dispense Switch  
Pressing and holding switch will initiate product flow from the respective nozzle; releasing the switch will stop  
the flow.  
B. Hidden Switch  
These switches are used to access, change and exit the dispenser program mode.  
C. Lock Switch  
This switch is used to lockout the dispensing capabilities.  
B
D
D
B
E
C
E
FIG 6 Portion Control Models  
B. Hidden Switch  
These switches are used to access, change and exit the dispenser program mode.  
C. Lock Switch  
This switch is used to lockout the dispensing capabilities.  
D. Product Dispense Switch  
Momentarily pressing and releasing one of the switches will initiate a timed dispense. Each station has three  
different timed dispenses which are preset at the factory. Refer to DISPENSER USE section for preset volumes  
and adjustment procedures.  
E. Plus/Stop Switch  
This switch can be used to “top-off” a beverage. Pressing and holding switch will initiate product flow from  
the respective nozzle; releasing the switch will stop the flow. Momentarily pressing this switch during a timed  
dispense will stop the flow.  
35303 012703  
8
DISPENSER USE  
Press and Hold Models (Refer to Fig 5)  
1. Place a cup on the drip tray beneath the desired dispensing nozzle.  
2. Press and hold the “Product Dispense” switch until the beverage reaches the desired level, then release.  
Portion Control Models (Refer to Fig 6)  
1. Place a cup on the drip tray beneath the desired dispensing nozzle.  
2. Momentarily press the appropriate cup size switch to dispense the beverage. The dispenser is factory preset  
to produce the approximate beverage sizes as follows:  
Small (4.0 seconds): approximately 7 fl.oz. (207 ml)  
Medium (6.9 seconds): approximately 12 fl.oz. (355 ml)  
Large (9.1 seconds): approximately 16 fl.oz. (473 ml)  
The dispense times can be individually programmed by following the procedures described in ADJUST-  
MENT - Cup Size Programming.  
To stop a timed dispense, momentarily press the “+/Stop Switch”.  
3. To “top-off” a beverage, press and hold the “+/Stop Switch” until the beverage reaches the desired level, then  
release.  
35303 012703  
9
CLEANING & PREVENTIVE MAINTENANCE  
General Cleaning and Sanitizing Procedures  
Note: The Bunn Juice Dispenser incorporates a rinse reminder feature which lights  
the rinse led on the front panel when it is time to rinse. See dip switch function  
list to activate this feature.  
Daily: Rinse Procedure  
Tools required: 32 oz. (946 ml) minimum empty container  
1. Open the refrigerated compartment’s door to access the “DISPENSE/RINSE”  
Knobs Fig 7.  
2. Select the stations that will be rinsed and then rotate the appropriate Knob(s) to  
the rinse position. It is recommended that ALL dispense heads be rinsed daily.  
Note: If a station is in service lockout, leave its knob in the Dispense position.  
3. Close the refrigerated compartment’s door.  
4. Place the empty container under the dispense nozzle to catch the rinse water.  
FIG 7 Dispense/Rinse Switch  
(CAUTION: THE BUNN JUICE DISPENSER CAN BE PLUMBED FOR A HOT WATER RINSE. RINSE WATER CAUGHT  
IN THIS STEP SHOULD BE HANDLED WITH EXTREME CARE.)  
5. PressandreleasetheappropriateProductDispenseSwitchFig5. Thiswillinitiateatimedrinsecycle. Portion  
control users can press any of the 3 “Product Dispense Switches” Fig 6, to initiate a timed rinse cycle.  
6. Repeat for each dispense head.  
7. Open the refrigerated compartment’s door and return each knob to the dispense position.  
8. Actuate the station’s Dispense Switch until concentrate appears from the dispense nozzle.  
Daily: Parts Washing  
1. Remove and wash the dispense nozzle(s), mixing element(s), drip tray and drip tray cover in a mild detergent  
solution. Rinse thoroughly.  
2. Wipe splash panel, areas around dispense nozzle(s), and drip trough in refrigerated compartment with a clean,  
damp cloth.  
Weekly: Sanitizing  
Tools required: Nozzle tubing (BUNN-O-MATIC part number 03289.1002) recommended when sanitizing multiple  
dispense heads simultaneously, 1 empty 5 gallon (18.9 L) bucket, 1 packet of Kay 5 sanitizer, and clean, empty  
concentrate containers.  
Note: The Bunn juice dispenser features a semiautomatic sanitizing program. When sanitizing multiple heads  
simultaneously, attach Bunn sanitize tubing (BUNN-O-MATIC part number 03289.1002) on the end of each  
dispense nozzle and run tubing to the 5 gallon (18.9 L) bucket.  
1. Remove any juice concentrate from the dispenser and store in a separate refrigerated compartment.  
2. Perform the rinse procedures as previously described. (Note: If the dispenser is plumbed for hot water rinse,  
proceed to step 9.)  
3. Fill clean empty concentrate container(s) with approximately 32 oz. (946 ml) of the hot tap water (approxi-  
mately140°F(60°C). Loadthecontainersofhotwaterintothedispenser(justlikeconcentrate). Verifytherinse  
knobs are in the “DISPENSE” position.  
4. Remove the drip tray and verify that the nozzle tubes are positioned within the empty bucket.  
5. Press and hold the “Sanitize Switch” Fig 5, located on the front left portion of the base, for 5 seconds. The  
“SANITIZE” indicator on the front panel will begin to flash and the beeper will sound twice indicating that you  
have entered the sanitize mode.  
35303 012703  
10  
CLEANING (cont)  
6. Select the dispense stations by pressing the “Dispense Switch” for that station. Use the “+/Stop Switch” for  
portion contol dispensers. The “REFILL” indicator will light and the beeper will sound for the dispense head  
selected.  
7. Oncethedispenseheadshavebeenselected,pressandholdtheSanitizeSwitchfor5secondsagaintoinitiate  
the automatic cycle. (When the cycle is initiated the “SANITIZE” indicator lights steadily and the “REFILL”  
indicator for each station being sanitized will flash.)  
Note: The sanitize routine takes 8 minutes. During the sanitize routine the following steps will occur in sequence:  
A) The pumps at the selected dispense heads will run for 1 minute, or until the bottles filled  
with hot water empty, whichever occurs first.  
B) The dispenser will sit idle for 5 minutes.  
C) The pumps at the selected dispense heads will run for 2 minutes or until the bottles filled  
with hot water empty, whichever occurs first.  
D) The beeper will sound once every 3 seconds to indicate completion of the sanitize  
routine.  
Note:Toterminateasanitizeprogrammid-cycle, momentarilypressandreleasetheSanitizeSwitchandproceed  
to step 17. The sanitize program should be restarted from step 1 to ensure proper sanitization.  
8. Once the cycle is completed, disconnect the sanitizing hose(s) from the nozzle(s) and empty the bucket.  
9. Remove each dispense nozzle and mixing element and run under hot tap water to remove excess pulp.  
10. Prepare 2.5 gal. (9.46 L) of sanitizing solution by dissolving 1 packet of Kay 5 sanitizer into 2.5 gal. (9.46 L)  
of 120°F (48.9°C) water to ensure 100 ppm of available chlorine.  
11. Placenozzle(s)andmixingelement(s)inaseparate1quartcontainerofsanitizingsolutionandmixthoroughly.  
Allow the part to soak for 2 minutes.  
12. Clean the dispense nozzle receptacle(s) (dispense valves) with the sanitizing solution and a soft bristle brush.  
13. Clean the concentrate bottle’s inlet adapter(s) using the sanitizing solution and a soft bristle brush.  
14. Replace the mixing element(s) and nozzle(s), reattach the sanitizing hose(s) to the nozzle(s), and insert the  
hoses into the catch bucket.  
15. Fill approximately 96 ounces (2.8 L) of clean sanitizing solution into clean, empty concentrate container(s).  
Do not use the sanitizing solution used in step 11. Load the containers into the dispenser.  
16. Repeat steps 5 through 8.  
Note: The sanitize routine takes 8 minutes. During the sanitize routine the following steps will occur in sequence:  
A) The pumps at the selected dispense heads will run for 1 minute, or until the bottles filled  
with sanitizing solution empty, whichever occurs first.  
B) The dispenser will sit idle for 5 minutes.  
C) The pumps at the selected dispense heads will run for 2 minutes or until the bottles filled  
with sanitizing solution empty, whichever occurs first.  
D) The beeper will sound once every 3 seconds to indicate completion of the sanitize  
routine.  
17. Replace the sanitizing solution with concentrate and reattach the drip tray.  
18. Activate a rinse cycle at each station as described in DAILY RINSE PROCEDURE.  
19. At each station, actuate the Dispense Switch until juice appears. Then pour one 12 ounce (354.9 ml) glass of  
juice and discard.  
20. Wipe internal and external surfaces with a clean, damp cloth.  
35303 012703  
11  
CLEANING (cont)  
Monthly: Clean Condenser Air Filter  
1. Remove the condenser air filter located on the rear of the dispenser.  
2. Using a water spray, clean the air filter.  
Annually: Replace Pump Tubing  
1. Open dispenser door.  
2. Remove all product containers and place them in a refrigerated (35-40 degrees F [1.6-4.4 degrees C])  
environment. Disconnect all connections to ambient products from the bottle adapter.  
3. Close the dispenser door and dispense product at each station until the product runs clear.  
4. Disconnect dispenser from power source.  
5. Remove the DISPENSE/RINSE knobs Fig 7, all dispense nozzles, and the dispense platform cover.  
6. Shut off the dispenser platform water valve located on the dispense platform. Disconnect the dispense  
platform’s water lines from the supply lines inside the refrigerated cabinet and disconnect the wiring  
connections from the cabinet receptacles.  
7. Release the latch securing the dispense platform to the cabinet .  
8. Slowly pull the dispense platform forward to allow access to the rear wiring harness connector.  
9. Disconnect the rear wiring harness connector from its receptacle.  
10. Pull the dispense platform completely out of the cabinet and place it on a flat work surface.  
11. Close the dispenser door.  
12. Remove the screw securing the tubing retainer plate to the pump body and set it and the tubing retainer plate  
aside.  
13. Gently pull the socket head screw from its notch in the pump body, releasing the spring tension on the pump  
band.  
14. Gently pull the pump tube from around the pump’s rotor.  
15. Inspect the pump band for signs of wear. Replace if necessary.  
16. Release the clamps securing the old pump tubing to the plastic elbows.  
17. Pull the plastic elbows from the old pump tubing, and discard the old pump tubing.  
18. Insert the plastic elbows into the new pump tubing and secure it with the clamps.  
19. Apply lubricant (BUNN-O-MATIC part number M2548.0000) to the new pump tubing’s rotor side.  
20. Gently wrap the new pump tubing around the pump’s rotor, making sure that the elbows and clamps end up  
on the top-side of the pump body and don’t protrude through the exit slots.  
21. Replace the socket-head screw into its notch in the pump body.  
22. Replace the tubing retainer plate and its retaining screw.  
23. Repeat steps 12 through 21 for the remaining pumps.  
24. Replace the dispense platform into the refrigerated cabinet, making sure to reconnect all electrical and water  
connections.  
25. Turn the dispense platform water valve to the open position. Check for leaks.  
26. Replace the dispense platform cover, DISPENSE/RINSE knobs and dispense nozzles.  
27. Turn power on to dispenser.  
28. Turn all DISPENSE/RINSE knobs to the RINSE positions. Close the door and run a rinse at each station. Check  
for leaks.  
29. Replace product shelf and product containers. Reconnect any connections to ambient product containers.  
30. Prime the pumps as described in “PRIMING” in the Initial Fill Section.  
35303 012703  
12  
ADJUSTMENT & OPTIONAL SETTINGS  
SETTING THE MIX RATIO/BRIX  
Ratio Cup Method  
1. Adjust the water flow as described in Water Flow Testing and Adjustment.  
2. Remove the dispense nozzle from the appropriate dispense position.  
3. Assemble, lubricate, and install the Flow Separator Assembly (BUNN-O-MATIC part number 32629.0000) into  
the dispense nozzle receptacle (dispense valve,) making sure to point the arrow on the separator body away  
from the dispenser.  
4. Place an empty container under the Flow Separator Assembly.  
5. Dispensers with Press and Hold Feature:  
Press and hold the “Product Dispense Switch” Fig 5, until water and concentrate begin flowing freely from  
the Flow Separator Assembly nozzles.  
Dispensers with Portion Control Feature:  
Press and hold the “+/Stop Switch” Fig 6, until water and concentrate begin flowing freely from the Flow  
Separator Assembly nozzles.  
6. Place the empty brixing cup (BUNN-O-MATIC part number 33095.0000) under the Flow Separator Assembly  
nozzles, small (concentrate) chamber to the left and large (water) chamber to the right.  
7. Dispensers with Press and Hold Feature:  
Press and hold the “Product Dispense Switch” until concentrate reaches the 1 oz. (black line) mark.  
Dispensers with Portion Control Feature:  
Press and hold the “+/Stop Switch” until concentrate reaches the 1 oz. (black line) mark.  
8. Read the level in the water chamber. This reading directly determines the mix ratio (i.e. If the water level reads  
4.0 oz., then the mix ratio is 4 [water] + 1 [concentrate].)  
9. Adjust the pump speed (down to increase the ratio, up to decrease the ratio) to achieve the correct mix ratio  
as described in Pump Speed Programming.  
10. Remove the Flow Separator Assembly and replace the dispense nozzle assembly into the dispense nozzle  
receptacle (dispense valve.)  
Temperature Compensated Refractometer Method  
1. Adjust the water flow as described in Water Flow Testing and Adjustment.  
2. Place an empty container under the appropriate dispense nozzle.  
3. Dispensers with Press and Hold Feature:  
Press and hold the “Product Dispense Switch” Fig 5, until water and concentrate begin flowing freely from  
the dispense nozzle.  
Dispensers with Portion Control Feature:  
Pressandholdthe+/StopSwitchFig6,untilwaterandconcentratebeginflowingfreelyfromthedispense  
nozzle.  
4. Discard the product caught previously and place the empty container back under the dispense nozzle.  
5. Dispensers with Press and Hold Feature:  
Press and hold the “Product Dispense Switch” until the cup is filled.  
Dispensers with Portion Control Feature:  
Press and hold the “+/Stop Switch” until the cup is filled.  
6. Stir the contents of the cup, and use the refractometer (according to the manufacturer’s instructions) to check  
the brix %.  
7. Adjust the pump speed (down to decrease the brix %; up to increase the brix %) to achieve the correct brix  
% as described in Pump Speed Programming.  
35303 012703  
13  
ADJUSTMENT & OPTIONAL SETTINGS (cont)  
Water Flow Testing and Adjustment  
1. EnterthePumpSpeedProgrammingmodebysimultaneouslypress-  
ing both “Hidden Switches” Fig 5 or Fig 6. Note that the beeper sounds  
twice and that the “PROGRAM” indicator begins flashing.  
2. Place a graduated measuring cup or the large chamber of the empty  
brixing cup (BUNN-O-MATIC part number 33095.0000) under the  
appropriate dispense nozzle.  
3. Press and hold the desired “Product Dispense Switch” Fig 5 (“+/Stop  
Switch” Fig 6, for portion control dispensers) for 5 seconds. Note that  
the beeper sounds once per second (6 times, total) during this period.  
P2253.70  
FIG 8 Adjusting Water Flow  
4. Attheendofthe5secondperiod, theselectedpositionwilldispensewater(noconcentrate)foronly3seconds.  
5. Measure the water dispensed.  
6. Adjust the water flow rate Fig 8, (clockwise to increase flow rate; counterclockwise to decrease flow rate) to  
the corresponding product mix ratio as follows:  
Mix Ratio  
(water + concentrate)  
2+1  
Adjust water flow rate to:  
Product  
Brix %  
3.75 fluid ounces (111 ml)  
per 3-second test  
Prune Juice  
Other  
16.0%  
*
Orange Juice  
Pineapple Juice  
Cranberry Fruit Cocktail  
Grapefruit Juice  
Lemonade  
11.8%  
12.8%  
14.0%  
10.6%  
4+1  
5+1  
4.5 fluid ounces (133 ml)  
per 3-second test  
Apple Juice  
Fruit Punch  
Grape Juice  
Other  
12.0%  
13.0%  
3+1 through 7+1  
Above 7+1  
*
*
6.0 fluid ounces (177 ml)  
per 3-second test  
Other  
Note: Information for specific products listed in this table is to be used for reference only. Consult the  
product label for exact mix ratio and/or brix %. See product label for target brix %.  
7. Repeat steps 3 through 6 as necessary until the correct water flow rate is achieved.  
8. Repeat steps 3 through 7 for the remaining dispense positions.  
9. Exit the “Pump Speed Programming” mode by simultaneously pressing both “Hidden Switches”. Note that the  
beeper sounds twice and the “PROGRAM” indicator extinguishes.  
Pump Speed Programming  
1. Enter the “Pump Speed Programming” mode by simultaneously pressing both “Hidden Switches”. Note that  
the beeper sounds twice and that the “PROGRAM” indicator begins flashing.  
2. To increase the pump speed, press and hold the right-hand “Hidden Switch” (filled circle) and then  
momentarily press the “Product Dispense Switch” Fig 5 (“+/STOP Switch” Fig 6, for portion control  
dispensers). Each time the “Product Dispense Switch “(+/STOP Switch”) is pressed, the motor speed is  
increased by one step (5 revolutions per minute [RPM].) Note that each step is confirmed by a single flash of  
the appropriate “REFILL” indicator and a single tone from the beeper.  
3. To decrease the pump speed, press and hold the left-hand “Hidden Switch” (half-filled circle) and then  
momentarilypresstheProductDispenseSwitch(“+/STOPSwitchforportioncontroldispensers). Eachtime  
35303 012703  
14  
ADJUSTMENT & OPTIONAL SETTINGS (cont)  
theProductDispense(“+/STOP”)Switchispressed,themotorspeedisdecreasedbyonestep(5RPM.)Note  
that each step is confirmed by a single flash of the appropriate “REFILL” indicator and a single tone from the  
beeper.  
4. Repeat as necessary at the remaining dispense stations.  
5. Exit the “Pump Speed Programming” mode by simultaneously pressing both “Hidden Switches”. Note that the  
beeper sounds twice and that the “PROGRAM” indicator extinguishes.  
Cup Size Programming (Portion Control Dispensers Only)  
1. Enter the “Cup Size Programming” mode by simultaneously pressing the “LARGE” and “SMALL” cup size  
switches at any dispense station. Note that the beeper sounds twice and that the “PROGRAM” indicator lights  
steadily.  
2. Press and hold the desired cup size switch at the appropriate dispense position until the correct cup volume  
is achieved. Top up as necessary by momentarily pressing the same cup size switch. Note that if DIP switch  
#2onthecontrolboardissettotheonposition, concentratemustbepresentinordertodispenseorprogram  
cup sizes.  
3. Repeat as necessary for the remaining cup sizes and dispense stations.  
4. ExittheCupSizeProgrammingmodebypressinganyofthe+/STOPSwitches”.Notethatthebeepersounds  
twice and that the “PROGRAM” indicator extinguishes.  
Dispenser Lockout  
Dispense and Rinse functions of the dispenser can be electronically locked-out to prevent unauthorized use of the  
dispenser, while keeping the refrigeration system running.  
1. Enter the “Pump Speed Programming” mode by simultaneously pressing both “Hidden Switches”. Note that  
the beeper sounds twice and that the “PROGRAM” indicator begins flashing.  
2. Enter a “Lockout” password as follows:  
a) Press and hold the left hand “Hidden Switch”.  
b) In a 5 second period, press and release the “Lock Switch”  
the number of times that you want  
the password set to (maximum of 10.) For example: If you want the password set to 3, press and release the  
“Lock Switch” 3 times in the 5 second period.  
c) Release the “Hidden Switch”.  
d) At the end of the 5 second period, the password will be confirmed by the “REFILL” indicators flashing the  
password.  
3. Exit the “Pump Speed Programming” mode by simultaneously pressing both “Hidden Switches”. Note that the  
beeper sounds twice and that the “PROGRAM” indicator extinguishes.  
4. To lockout the dispenser, proceed as follows:  
a) Press and hold either “Hidden Switch”.  
b) In a 5 second period, press and release the “Lock Switch” the “password” number of times. For example:  
If the password is set to 3, press and release the “Lock Switch” 3 times in the 5 second period.  
c) Release the “Hidden Switch”.  
d) At the end of the 5 second period, the dispenser will extinguish the merchandising lamp, and all dispense  
functions will be disabled.  
5. To enable the dispenser, proceed as follows:  
a) Press and hold either “Hidden Switch”.  
b) In a 5 second period, press and release the “Lock Switch” the “password” number of times. For example:  
If the password is set to 3, press and release the “Lock Switch” 3 times in the 5 second period.  
c) Release the “Hidden Switch”.  
d) At the end of the 5 second period, the dispenser will light the merchandising lamp, and dispense functions  
will be enabled.  
35303 012703  
15  
ADJUSTMENT & OPTIONAL SETTINGS (cont)  
6. If the password is forgotten, it can be reset to “0” (dispenser lockout disabled) as follows:  
Note: The following procedure also clears the programming and service lockout password.  
a) Disconnect the dispenser from its power source.  
b) Place the “Refrigeration Switch” Fig 3, in the OFF (rearward) position.  
c) While pressing and holding the “Lock Switch”, connect the dispenser to its power source.  
d) Continue to hold the “Lock Switch” until the dispenser beeps three times, then release.  
e) The passwords are now returned to “0” (no programming or service lockout password/dispenser lockout  
disabled.)  
f) After 3 minutes, place the “Refrigeration Switch” in the ON (forward) position.  
Service Lockout  
Should a dispense station become inoperative and require service, the station’s dispense and rinse functions can  
be independently locked out, while keeping the remaining stations running.  
1. ToplaceasingledispensestationinServiceLockout,openthedispenserdoor, pressandholdeitherHidden  
Switch” and the desired dispense station “Product Dispense” (“+/Stop”) switch for 10 seconds.  
2. At the end of the 10 second period, the beeper will sound a double tone and the dispense position will be  
disabled. Place the DISPENSE/RINSE Knob to “DISPINSE” and close the dispenser door.  
3. To remove a dispense station from “Service Lockout,” press and hold either “Hidden Switch” and the desired  
dispense station “Product Dispense” (“+/Stop”) switch for 10 seconds.  
4. At the end of the 10 second period, the beeper will sound a double tone and the dispense position will be  
enabled. Close the dispenser door.  
Password Protection  
The programming modes and service lockout function may be password protected to prevent accidental or  
unauthorized access to these features. The dispenser is shipped from the factory with a password of “0” (no  
password.)  
1. Enter the “Pump Speed Programming” mode by simultaneously pressing both “Hidden switches”. Note that  
the beeper sounds twice and that the “PROGRAM” indicator begins flashing.  
2. Program a password as follows:  
a) Press and hold either “Hidden Switch”.  
b) In a 5 second period, press and release the “Sanitize Switch” the number of times that you want the  
password set to (maximum of 10.) For example: If you want the password set to 3, press and release the  
“Sanitize Switch” 3 times in the 5 second period.  
Note:Toresetpasswordto0(nopassword)pressandholdtheSanitizeSwitch”,withouteitherHiddenSwitch”  
pressed,forthe5secondperiod.Whenthepasswordresetsto0”,thebeeperwillsoundandtheWaterindicators  
will illuminate for approximately 2 seconds.  
c) Release the “Hidden Switch”.  
d) At the end of the 5 second period, the password will be confirmed by the “WATER” indicators flashing the  
password.  
e) From this point forward, the password must be entered before access is allowed to programming modes  
or the service lockout function.  
35303 012703  
16  
ADJUSTMENT & OPTIONAL SETTINGS (cont)  
3. To enter the password, proceed as follows:  
a) Press and hold either “Hidden Switch”.  
b) In a 5 second period, press and release the “Sanitize Switch” the password number of times. For  
example: If the password is set to 3, press and release the “Sanitize Switch” 3 times in the 5 second period.  
c) Release the “Hidden Switch”.  
d) Wait for the password to be confirmed by the flashing of the “Water” indicators.  
e) Enter the desired program mode or select service lockout as normal within the next 5 seconds.  
Note: If the program mode/service lockout is not selected within 5 seconds, it will be necessary to re-enter the  
password.  
4. If the password is forgotten, it can be reset to “0” (no password) as follows:  
Note: The following procedure also clears the dispenser lockout password.  
f) Disconnect the dispenser from its power source.  
g) Place the “Refrigeration Switch” in the OFF (rearward) position.  
h) While pressing and holding the “Lock Switch”, connect the dispenser to its power source.  
i) Continue to hold the “Lock Switch” until the dispenser beeps three times, then release.  
j) The passwords are now returned to “0” (no programming or service lockout password/dispenser lockout  
disabled.)  
k) After 3 minutes, place the “Refrigeration Switch” in the ON (forward) position).  
35303 012703  
17  
Dispense Fault List  
“REFILL” indicator  
2 flashes  
Beeper  
2 beeps  
3 beeps  
4 beeps  
5 beeps  
3 beeps  
Fault  
Dispense station locked out.  
DISPENSE/RINSE sensing fault.  
DISPENSE/RINSE knob mis-positioned.  
Pump motor stalled/speed sensor inoperative.  
Dispenser locked out.  
3 flashes  
4 flashes  
5 flashes  
All “REFILL”  
indicators flash  
3 times  
Cooling Fault List  
Fault Code  
“COOLING”  
indicator  
8 flashes every  
5 seconds  
7 flashes every  
5 seconds  
6 flashes every  
5 seconds  
5 flashes every  
5 seconds  
4 flashes every  
5 seconds  
3 flashes every  
5 seconds  
DBC display  
(optional)  
Fault  
Fault  
Priority  
1
8
7
6
5
4
3
0
2
1
fault 8  
Bath water level low.  
(Also lights all “WATER” indicators)  
Bath temperature probe short circuit.  
fault 7  
fault 6  
2
3
4
5
6
7
8
9
Bath temperature probe open circuit.  
Cabinet temperature probe short circuit.  
Cabinet temperature probe open circuit.  
fault 5  
fault 4  
fault 3  
Cooling system failure  
(disables all dispense functions)  
Bath and cabinet temperatures excessive.  
On steady  
Bath/cabinet  
temperatures  
2 flashes every  
5 seconds  
1 flash every  
5 seconds  
Bath/cabinet  
temperatures  
Bath/cabinet  
temperatures  
Bath temperature excessive.  
Cabinet temperature excessive. (Disables all  
dispense functions, flashes, all REFILL and  
WATER indicators, and sounds the beeper  
when temperature is excessive for more than  
6 hours.)  
35303 012703  
18  
Dip Switch Function List  
Dip Switch Controls  
Off  
Inactive  
On  
1
2
3
4
5
6
“REFILL” indicator when “concentrate out” is detected.  
Active  
Lockout dispense components when “concentrate out” is detected. Inactive  
Active (Note)  
Number of positions that can dispense/rinse simultaneously.  
3
Off  
2
On  
Rinse timer  
Audio feedback during dispenses.  
Future use.  
On  
Off  
None  
None  
Note: When dip switch 2 is in the “on” position, the “REFILL” indicator is active, regardless of dip switch 1  
position.  
35303 012703  
19  
COOLANT SCHEMATIC DIAGRAM  
35303 012703  
20  
SCHEMATIC WIRING DIAGRAM  
GRN  
L1  
N
OPTIONAL  
WHI  
GRN  
BLK  
GRN  
BLK  
BLK  
FLUORESCENT  
LAMP  
BALLAST  
BLK  
WHI  
WHI/GRN  
K1  
ON/OFF  
WHI  
WHI  
BLU/BLK  
BRN/BLK  
LAMP ASSY.  
BLK  
TRANSFORMER  
K1  
BLK  
BLU  
CONDENSOR FAN  
WHI  
WHI/BLU  
WHI  
BLU/BLK  
MOTOR  
GRY  
COMPRESSOR ASSEMBLY  
RECT  
K2  
1
10  
+
WHI  
WHI/GRY  
LIMIT  
THERMOSTAT  
RINSE  
SOL  
BLU/BLK  
RED/BLK  
RED/BLK  
K2  
COMP.  
GRN  
WHI  
WHI  
BLK  
PUMP  
#2  
PUMP  
#1  
VIO  
BLU  
VIO  
WHI/VIO  
ORN  
ORN  
YEL  
WHI/ORN  
WHI/ORN  
WHI/VIO  
RED  
WHI/ORN  
WHI/VIO  
RED  
GRY  
GRY  
SANITIZE  
SWITCH  
J6-1  
J6-6  
GRY  
PNK  
VIO  
1
1
VIO  
ORN  
J9-1  
RED  
RED  
WHI/ORN  
VIO  
RED/BLK  
GRY  
GRY  
1
J9-6  
GRY  
WHI/VIO  
C
J8-1  
O
N
T
J6-12  
RED  
FAN BLK  
RED  
WHI/RED  
BEEPER  
J3-1  
J3-2  
R
O
L
GRN/YEL  
J1-1  
J1-5  
P
C
WHI/RED BLK  
WHI  
WHI  
J8-8  
J7-1  
RECIR.  
PUMP  
RED/BLK  
GRN/WHI  
BLU/WHI  
BLK/WHI  
WHI/ORN  
WHI/ORN  
GRY  
RED  
PNK  
B
O
A
R
D
GRN  
PNK  
WHI  
GRY  
J7-5  
ORN  
WHI  
RED  
RED/WHI  
BLK  
BLU/BLK  
GRN/BLK  
BLU  
ORN/BLK  
WHI/BLK  
GRN  
J1-10  
J1-18  
1
6
GRY  
WHI/BLK  
J7-10  
WHT/VIO  
VIO  
WHI  
WHI/RED  
GRN  
1
1
WHI/VIO  
J7-16  
P
R
O
B
E
t°  
CABINET  
THERMISTOR  
t°  
To Switch Unit Assembly  
WATER BATH  
THERMISTOR  
1
16  
SWITCH UNIT ASSEMBLY  
(Push Button Control models)  
SHIELD  
1
VIO  
ORN  
12  
#1 REFILL  
SENSOR  
#2 REFILL  
SENSOR  
#1 RINSE &  
#2 RINSE &  
DISPENSE LIMIT DISPENSE LIMIT  
RINSE  
RINSE  
DISPENSE  
DISPENSE  
1
1
SWITCH UNIT ASSEMBLY  
(Portion Control Models)  
1
16  
SHEILD  
#1 DISPENSE  
WHI/VIO  
#2 DISPENSE  
WHI/ORN  
RED/BLK  
RED/BLK  
SOL  
SOL  
120 VOLTS AC  
2 WIRE  
SINGLE PHASE  
35303 121203  
21  
SCHEMATIC WIRING DIAGRAM  
GRN  
GRN  
GRN  
BLK  
BLK  
WHI  
WHI  
BLU/BLK  
BRN/BLK  
LAMP ASSY.  
BLK  
TRANSFORMER  
BLK  
BLU  
CONDENSOR FAN  
BLU/BLK  
WHI/BLU  
WHI  
MOTOR  
GRY  
COMPRESSOR ASSEMBLY  
RECT  
K2  
+
LIMIT  
THERMOSTAT  
RINSE  
SOL  
RED/BLK  
RED/BLK  
K2  
COMP.  
PUMP  
#2  
PUMP  
#1  
VIO  
WHI/VIO  
ORN  
WHI/ORN  
WHI/ORN  
WHI/VIO  
RED  
GRY  
SANITIZE  
SWITCH  
J6-1  
J6-6  
GRY  
PNK  
VIO  
VIO  
ORN  
J9-1  
RED  
RED  
WHI/ORN  
VIO  
RED/BLK  
GRY  
GRY  
J9-6  
GRY  
WHI/VIO  
C
O
N
T
R
O
L
J8-1  
J6-12  
RED  
FAN BLK  
RED  
WHI/RED  
BEEPER  
J3-1  
J3-2  
J1-1  
J1-5  
P
C
WHI/RED BLK  
WHI  
WHI  
J8-8  
J7-1  
RECIR.  
PUMP  
RED/BLK  
GRN/WHI  
BLU/WHI  
BLK/WHI  
B
O
A
R
D
WHI/ORN  
J7-5  
ORN  
WHI  
RED  
RED/WHI  
BLK  
BLU/BLK  
GRN/BLK  
BLU  
ORN/BLK  
WHI/BLK  
GRN  
GRY  
RED  
PNK  
J1-10  
J1-18  
J7-10  
WHT/VIO  
VIO  
WHI  
WHI/RED  
WHI/VIO  
J7-16  
P
R
O
B
E
t°  
1
VIO  
ORN  
12  
#1 RINSE &  
#2 RINSE &  
DISPENSE LIMIT DISPENSE LIMIT  
#1 DISPENSE  
WHI/VIO  
#2 DISPENSE  
WHI/ORN  
RED/BLK  
RED/BLK  
SOL  
SOL  
35303 121203  
22  

Brother IntelliFAX 2480C User Manual
Brother MFC 3100C User Manual
Brother USUARIO MFC J270W User Manual
Canon PIXMA MP280 Inkjet Multifunction Printer 4498B030 User Manual
Canon Wireless Photo All In One 8331B040 User Manual
Daewoo DSB F183L User Manual
Goldstar M6003R User Manual
Goodman Mfg Co LP Air Conditioner GSX130611A User Manual
HP Hewlett Packard Hewlett Packard All in One Printer L1750 User Manual
HP Hewlett Packard LASERJET 9050MFP User Manual