JVC Digital Camera VN C30U User Manual

VN-C30U  
ADDITIONS TO INSTRUCTIONS  
– Control from Web Browser –  
This instruction manual is printed on  
INSTRUCTIONS  
recycled paper.  
Thank you for purchasing the JVC VN-C30U.  
For Customer Use:  
To gain maximum benefit from this product, read this  
Enter below the Serial No. which is  
located on the body. Retain this  
information for future reference.  
instruction manual carefully befor use and retain it for future  
reference.  
The serial number is very important for maintaining quality of  
your product. At the time of purchase, check to see that the  
serial number is correctly printed on the top of the unit and  
that the serial numbers on the unit and warranty match.  
Model No.  
VN-C30U  
Serial No.  
LWT0031-001D  
 
1. Setup  
1-1 Changing the IP Address of the PC  
Select the [Start] button then select [Settings] – [Control Panel] –  
[Network] to display the [Network] settings panel.  
1 Select item “TCP/IP” then click on  
<Properties>.  
2 Before making a change, always make  
a note of the original IP address.  
Change the IP address to:  
192.168.0.3  
Set [Subnet Mask] to a value suitable for  
the setting operation. If a suitable value  
is unknown, check with the network  
administrator.  
3 Click on <OK> and then  
restart the PC.  
3
 
Web Page Illustrations Used inThis Manual  
Hereafter, the figures entitled VN-C30U Page show a display of the web  
page data of the VN-C30U (including images captured by the cameras) by  
the web page display function of the web browser.  
Due to this mechanism, the format and character font of the displayed web  
pages may be variable depending on the types and settings of the web  
browser in use. Should the operation be hindered due to a lack of any of the  
screen display items that should be displayed, adopt measures for displaying  
all items by resizing the window, etc.  
The figures in this manual are based on Netscape web page displays.  
When the browser in use is Netscape  
• When a moving image of the VN-C30U is displayed, the web page  
display cannot be updated by changing the Netscape window size. In  
this case, click on the <Update> button on the Netscape window to  
update the web page display.  
When the browser in use is Internet Explorer  
• After the password has been changed, the password entry confirmation  
window may ask for the password twice. In this case, enter the same  
password twice.  
• When the VN-C30U is connected through a proxy server, the correct  
pan/tilt positions may sometimes not be enabled to be displayed. In  
this case, click “Pan/Tilt” a few times until the correct display is obtained.  
4
 
1-2 Changing the internal settings  
Start the web browser.  
In the web browser, specify the factory-set web page address of the  
VN-C30U. (Direct specification of the factory-set web page address  
enables the web browser to display the VN-C30U Top Page.)  
Caution  
If a proxy server is set for accessing the Internet, a direct specification  
may not be permitted. In this case, change the proxy setting to permit  
direct address specification.  
Display with Netscape  
Note:  
In this manual, the terms “Top page” and “Home page” are used as  
described below:  
Top page  
: Indicates “index-e.html”  
Home page : • If the default page (See page 8) is set to valid, the  
specified html page is indicated.  
• If the default page is set to invalid, “index-e.html” is  
indicated.  
5
 
The VN-C30U Top page appears.  
CAUTION  
• The background changes to blue when the image mode of the VN-C30U  
is set to the MPEG mode.  
• The Top page will not appear if the “HTTP Viewing” is set to “Disable”  
using the Setup Tool.  
Instead the message “403 Forbidden” will be displayed.  
VN-C30U Top page  
Click on <Settings>.  
VN-C30U Settings page  
6
 
The setup consists of changing the contents of [Other Settings]. (The same  
setup is also available using the Setting tool provided with the standard  
controller.)  
VN-C30U Settings page [Other Settings]  
Items in [Other Settings]  
[DHCP]  
[IP Address]  
Set this to “Enable” when the DHCP is used.  
To change to the IP address assigned to or approved for  
the network administrator. (This is can be changed only  
when DHCP is not used.)  
[Subnet Mask]  
Similarly to the IP address, to set the value assigned to  
or approved for the network administrator  
[Default Gateway] To set the IP address of the default gateway  
If this is not used, set “0.0.0.0”.  
[Host Name]  
To specify the host name using up to 8 alphanumeric  
characters  
This should be set when access linkage using a host  
name is required in an environment allowing the use of  
the DNS (Domain Name System). The host name is  
displayed in the title bars of sub-windows including the  
control windows.  
Do not specify anything when the host name is not used  
or unknown.  
[MAC Address]  
A physical address proper to each product.  
* This cannot be changed.  
7
 
[Program Version]  
[Password]  
Program version of the firmware in the VN-C30U  
unit.  
* This cannot be changed.  
To set the password using up to 8 alphanumeric  
characters.  
The same password should be entered twice at  
each level for confirmation.  
[Pan/Tilt Position]  
[Cache Control]  
To select whether the current pan/tilt positions  
are to be displayed in the control and  
configuration windows. (This is ineffective with  
the VN-C30U Ver. 2.)  
With a very small number of proxy servers that  
caches cgi, the pan/tilt control may not function  
correctly. In this case, inhibit the Cache operation  
by checking the cache box.  
[FTP Server Function]  
Set whether FTP Server is valid/invalid.  
If this is set to valid, it will be possible to upload  
various user HTML pages, GIF and JPEG image  
files, etc. to this unit using common FTP client  
software.  
* Uploaded files will all be placed directly under  
the “/user folder” directory.  
Access from a web browser can be done by  
user/aaa.html  
(When accessing “aaa.html” stored on FTP, the  
“192.168.0.2” denotes the IP address of this  
machine.)  
* The FTP user name is fixed as “Administrator”.  
For the FTP password, use the administrator  
level password.  
* When the “HTTP Viewing” is set to “Disable”  
using the Setup Tool, it will not be able to  
access the file uploaded with a Web browser.  
8
 
CAUTION  
• The allotted FTP user area is approximately 90 K bytes, however since  
this unit’s file system is generated dynamically, the actual storable  
capacity may be less than this in certain cases.  
• Folders cannot be created on this FTP server. Only file upload/delete/  
rename are possible.  
[Default Page Set-up]  
If “invalid”, it will be set to the regular VN-C30U  
Top Page.  
If “valid”, the HTML file you set will be used as  
the default page.  
*Default Page refers to the page that is displayed when only the IP address  
is specified.  
ATTENTION  
Even if the function is “valid”, if the HTML file specified here does not  
exist then a message such as “404: Not Found” will be displayed by the  
setting is made correctly.  
[HTTP Port]  
It is possible to change the port number of the  
HTTP Server on this unit to a number other than  
the default port 80 to raise the level of security.  
(Selectable range: 1-65535 excluding 20 and 21)  
If the HTTP Port is changed, access from web  
browser will be done as follows:  
192.168.0.2:12345/index.html  
(Example when Port 12345 is selected)  
When you don’t know or forget the HTTP Port  
number, use the provided Setup tool to check it.  
This enables setting the HTTP port automatically  
in order to resume a specified position number  
when the power is turned on or if the software is  
reset. (It is necessary to register a position in  
advance in the memory to enable this function.  
Refer to page 19.)  
[Default positioning]  
9
 
Password protection  
Access protection using a password is provided with the VN-C30U to  
restrict other connecting browsers (users). The access protection function  
provides three security levels, each of which is allowed to access the  
kinds of pages as shown in the following table.  
(For the configuration of the VN-C30U web pages, see page 14.)  
Level  
User  
Access Permission  
Image pages only.  
Operator  
Administrator  
Web pages other than the configuration pages.  
All web pages  
CAUTION  
• Never forget the current password for it cannot be canceled or changed  
unless it matches the password set at the administrator level.  
• Even when the user or operator level password is set, the password will  
not be asked for unless the administrator level password is set.  
10  
 
VN-C30U Configuration page  
[Other Settings]  
Click on <Apply> to update the settings.  
Confirm the changed IP address again. Click on <OK>  
if the entry is correct.  
CAUTION  
The confirmation window above is displayed after [IP Address], [Subnet  
Mask], [Host Name] and/or [HTTP Port] have been changed.  
When <OK> in this window is clicked, the VN-C30U unit is reset internally  
to update the IP address, etc. As this renders the IP address before change  
(factory-set value) ineffective, the connection to the VN-C30U is  
disconnected. The screen indicates that a connection cannot be  
established after the web browser has not been used for a while.This is a  
result of the change in the IP address. (The same is also true when the  
Port Number is changed.)  
11  
 
1-3 Restoring the IP address of the PC  
In the same way as section 1-1, select [Start] – [Settings] – [Control  
Panel] – [Network] to display the [Network] settings panel and change  
[TCP/IP Properties] to the original IP address that has been noted  
previously.  
After the change, restart the PC by following the displayed instruction  
message.  
2. VN-C30U Access Test  
This test confirms that the VN-C30U web pages may be browsed and  
displayed via the web browser using the set IP address or DNS host  
name.  
(For the configuration of the VN-C30U web pages, see page 14.)  
CAUTION  
If a proxy server is set for accessing the Internet, web pages may not be  
directly specified. In this case, change the proxy setting to permit direct  
address specification.  
Also, when the DNS is used, contact the network administrator to update  
the information related to the DNS address setting, etc.  
Enter: http:// <IP address> or <Host name>  
/
12  
 
The [User Name and Password Entry] request window appears (for access  
authorization).  
The user name is not used.  
For the password, enter the one of the  
three passwords that have been set.  
Click on <OK>.  
It is recommended to register the browsing information connection location  
(URL: Uniform Resource Locator).  
To speed up the display of VN-C30U web pages from your web browser,  
it is recommended to register the URL information during the access test  
using the set IP address or DNS host name.  
The registration uses “Bookmark” of Netscape or Internet Explorer. While  
a VN-C30U web page is displayed, perform the operation using the web  
browser’s menu to add the page to the “Bookmark”.  
Add Bookmark (Display with Netscape)  
13  
 
VN-C30U WEB PAGES  
– Display Items and Operation Description –  
The configuration of URLs inside the VN-C30U is as shown below.  
CAUTION  
Authorization of access (Security) right is required in the access of any URL.  
Security level  
<User>  
<Operator>  
<Administrator>  
Top page (index-e.html)  
Still image page (still-e.html)  
Moving image page (java-e.html)  
Pan/tilt controller (pan_tilt-e.html)  
Lens controller (lenz-e.html)  
Still image URL (still.jpg)  
Serverpush moving image  
URL (push.jpg)  
Configuration page (javaconfig-e.html)  
Configuration menus  
Image Quality Configuration  
(configimage-e.html)  
Java moving image URL  
(mjpeg.class)  
Alarm Configuration (alarm-e.html)  
Other Configurations (config-e.html)  
View Configuration (viewconfig-e.html)  
Position Memory Configuration  
(position-e.html)  
FTP Client Configuration (fpt-e.html)  
Top page: http://  
/index-e.html (  
*****  
: URL indicating the VN-C30U)  
*****  
This page is intended to provide links to other VN-C30U web pages.  
VN-C30U Top page  
VN-C30U still image  
The camera image at the  
moment browsing starts is  
displayed.  
Link buttons for web pages. (Operates with single clicks.)  
14  
 
Still Image Page: http://  
/still-e.html (  
*****  
: URL indicating the VN-C30U)  
*****  
This page displays only still images. The initial image is the camera image at  
the moment browsing starts. To update the image, perform the “Reload” or  
“Update” operation on the web browser. To save the image being displayed,  
perform the “Save As” operation on the web browser.  
VN-C30U Still Image page  
Hyperlink to the Home page  
This page displays only moving images. The displayed image is the camera  
image that is being updated automatically.  
CAUTION  
Do not attempt to save images in this page for it has not been compiled  
assuming the use of the “Save Image As” function of the web browser.  
Also do not attempt to save the entire web page for it has neither been  
compiled assuming the use of the “Save As” function.  
VN-C30U Moving Image page  
Buttons for displaying the sub-window  
for use in panning, tilting, zooming and  
position memory movement controls.  
Button for displaying the sub-window for  
use in the iris, focus and zoom settings.  
Hyperlink to the Home page.  
15  
 
Control windows  
[Pan/Tilt/Zoom] control window  
The sub-window shown below can be used for the control of panning, tilting,  
zooming and position movement.  
The VN-C30U unit incorporates a position memory storing up to 10 pan/tilt  
positions used in image capturing. Clicking one of the 10 (No.) buttons enables  
the camera to start the pan/tilt operation to the corresponding position stored  
in the memory. When the mouse pointer is placed over the Move Position  
button, the Pan/Tilt/Zoom location of each position will be displayed in Alt.  
The pan/tilt position can be changed using these 8 pan/tilt control buttons.  
The amount of movement per press of a pan/tilt button is the “Angle Step”.  
The current [Zoom Step] and [Angle  
Step] settings for the pan/tilt operation  
are displayed.  
Either setting can be changed by  
entering the desired angle value  
(integer) and clicking on the <Apply>  
button.  
The lens zooming can be changed  
using these two buttons. The amount  
of lens movement per press of the  
button is the “Zoom Step”.  
CAUTION  
Do not execute the pan/tilt operation until the web browser has completed  
loading the images of all the buttons.  
16  
 
[Lens] control window  
[Zoom] This setting controls zooming.  
Change the value and click on the <Apply> button to enable the  
lens to zoom in or out.  
[Focus] This setting controls focusing.  
When it is set to [Auto], the focusing is adjusted automatically.  
(Autofocusing)  
When it is set to [Manual], the focusing position can be specified  
as required. (Change the value on the right and click on the  
<Apply> button to set the lens to the specified focusing position.)  
[Iris]  
When it is set to [Auto], the iris is adjusted automatically according  
to the brightness of the object.  
When it is set to [Manual], the iris can be set as required, regardless  
of the brightness of the object. (Change the value on the right and  
click on the <Apply> button.)  
17  
 
Configuration Page:  
http://  
*****  
/javaconfig-e.html (  
: URL indicating the VN-C30U)  
*****  
This page is used for settings related to images and connections (setup).  
(A camera image updates automatically to be displayed as a moving image.)  
Moving image  
VN-C30U Settings page  
Hyperlink to the Home page  
Click on the desired setting button to  
display a sub-window for the setting item.  
18  
 
[Control] and [Lens] control windows  
See the descriptions in “Control windows”.  
[Position Memory Configuration] window  
Positions currently set in the position memory.  
VN-C30U Control page  
[Position Memory]  
Click on <Apply> to set  
the current pan/tilt position  
as a position stored in the  
position memory.  
[Image Quality Configuration] window  
Click on <Default> to  
reset all of the settings in  
the image quality-related  
menu to the factory-set  
values.  
Image quality-related setting items.  
After setting the desired items, click on <Apply> to make the settings valid. See  
the following table for a description of each item.  
19  
 
Item  
Effect  
Compression Rate The compression rate is inversely proportional to the image quality.  
When the compression rate is small, the image quality can be  
improved but the data quantity increases.  
Saturation  
This adjusts the development of colors.  
Increasing this value increases color saturation.  
White Balance When [AWB] is checked, the auto white balance circuit controls the  
white balance automatically.  
When [AWB] is not checked, the R Gain and B Gain settings are activated.  
Brightness  
• When [AGC] is checked, the gain of the internal amplifier is  
adjusted automatically according to the surrounding brightness.  
• When [BLC] is checked, the back light compensation function is  
activated. One of the five photo-metering areas from the pull-down  
menu can be selected. The brightness will be adjusted  
automatically based on the selected photo-metering area.  
CAUTION : The BLC function does not work effectively unless [AGC] is checked.  
Shutter Speed Select [1/60] for normal image capturing. To reduce flickering under  
fluorescent lighting, etc., select [1/100] if the local power voltage is  
50 Hz or [1/60] if it is 60 Hz.  
[View Configuration]  
window  
Item  
Effect  
Resolution  
Select the image size from “640 x 480”, “320 x 240” and “160 x 120”.  
When [Cornpensate aspect ration when 160 x 120 selected.] is checked,  
the image size of the “160 x 120” display becomes actually 160 x 112.  
JPEG Frame Rate Select the maximum number of frames transmitted from the VN-  
C30U per second.  
CAUTION  
The actual number of frames transmitted or displayed per second is dependent on the  
performance of the PC, type of web browser and LAN environment. In case communication  
faults involving the processing of other users are expected (particularly when the network  
environment is usually subjected to a relatively heavy load), it is recommended to set the frame  
rate to a lower value.  
When a large image size (640 x 480) is used, the upper limit of the frame rate is limited at 3 fps  
regardless of the setting made in [JPEG Frame Rate].  
Be sure to adjust [JPEG Frame Rate] in consideration of the number of simultaneous accesses  
to the unit.If its processing capability is exceeded, it will be impossible to perform correct operations  
including the web page display, movement and button operations.  
20  
 
[Alarm Configuration] window  
This window sets the action to be performed when an alarm signal is input.  
Alarm 1 or 2  
[On/Off]  
Check [On] when using the corresponding alarm input (1 or 2)  
and check [Off] when not using it.  
[Settings]  
An alarm input enables the camera movement to one of the  
positions stored in the position memory and an alarm signal  
output.  
• [Go to a Preset Position]  
Select one of the positions 1 to 10, which have been set in  
the VN-C30U [Position Memory Configuration] window. When  
an alarm is input, the camera will move to the specified  
position.  
• [Alarm Out]  
When “Yes” is selected, the alarm output outputs the signal  
set in [Alarm Out] below in the case of an alarm input.  
• [FTP]  
When “1” or a larger value is selected, the FTP client function  
will be enabled for a certain period according to the current  
FTP settings, even if the function is disabled by a setting. (To  
make this possible, the FTP settings should be set to enable  
FTP in advance.)  
21  
 
Relay Alarm  
When alarm signals are input one after another with an interval of a few seconds,  
an interlocked alarm input can be identified and enable another operation.  
Alarm Out  
[Enable/Disable]  
Check [Enable] to use the alarm output and [Disable]  
to not use it.  
[Configuration Items] These items are used to set the signal output from  
the alarm output terminal.  
• [Momentum]  
Set the time period for which the alarm output is to  
be continued.  
• [Value]  
Select whether the [High] or [Low] level signal is  
output as the alarm output.  
• [Power on Init]  
Select whether or not the alarm signal is output from  
the alarm output of VN-C30U at the moment it is  
turned ON.  
* Set the alarm output according to the output destination device.  
* After completing alarm configurations, be sure to confirm that the alarm  
operations are performed as intended.  
22  
 
[FTP Client Configuration] window  
FTP client function  
This function uploads the VN-C30U images (still images) periodically to an  
existing FTP server.  
This makes possible an image distribution service from a server and greatly  
increases the number of clients to whom images may be distributed.  
[FTP function] • [Available]: ........... Check to enable the FTP function.  
• [Not available]:..... Check to disable the FTP function.  
[Username]  
Enter the user name to be used in authentication with the  
FTP server.  
23  
 
[Password]  
Enter the password to be used in authentication  
with the FTP server. (The entered characters are  
displayed as “*”.)  
[Host IP Address]  
Enter the IP address of the upload destination FTP  
server.  
[FTP Port]  
Enter the upload destination FTP port number.  
[FTP Folder]  
Enter the upload destination folder name in the  
FTP server. If this is not entered, the images will  
be uploaded in the default folder.  
[Upload Interval]  
Enter the interval for image uploading to the FTP  
server. (It is possible to upload earliest by setting  
this item at 0 second.)  
[Disconnect every time]  
Check this box to disconnect the connection after  
every image uploading.  
* This makes it necessary to establish a  
connection before the next time an image is  
uploaded.  
[Error Recovery]  
[On connect error]  
Select the operation to be performed in case of  
an error related to the TCP connection or FTP  
authentication.  
• [Retry forever]: ........... The connection will be  
retried until the VN-  
C30U is turned OFF.  
[Retry in every * min]: .... The connection will be  
retried for the specified  
period.  
[On transfer error]  
Select the operation to be performed in case of  
a file transfer error while images are uploading.  
• If [Stop Uploading] ........................ is checked:  
The FTP function of the VN-C30U is disabled  
automatically in case of a transfer error.  
* To resume the FTP operation, check [Available]  
in [FTP function].  
24  
 
If [Stop Uploading] ...................... is not checked:  
The FTP function of the VN-C30U is not disabled  
in case of a transfer error. In this case, upload  
will be retried at every uploading interval.  
[Filename]  
[*.jpg]  
Enter the file name to be assigned to the uploaded  
image. (The latest image will overwrite this file.)  
* As the images are uploaded in the same file names,  
the FTP server retains only one image file.  
[Timestamp]  
When this is selected, the images will be uploaded  
by acquiring the current time from the NTP server (see  
below) and by naming the image file according to the  
current time data, in the format of “YYYY-MM-DD-HH-  
MM-SS-mmm”.  
* As the images are uploaded in different file names,  
the FTP server will retain the same number of image  
files as the number of uploaded images.  
[NTP Server IP Address]:  
Enter the IP address of the NTP (Network Time  
Protocol) server.  
[Camera Timezone GMT]:  
Enter the difference of the local time with respect to  
the Greenwich Mean Time.  
[Adjust in every * day * hour]:  
Specify the interval  
period for acquiring the correct time data from the  
NTP server for use in correcting the time error.  
25  
 
Note:  
• An NTP server is required for the NTP setting.  
• With Windows XP Home Edition and Windows XP Professional, NTP  
sever functions become enabled when they are installed in the standard  
procedure.  
• For Windows 2000, follow the procedure below to enable NTP server  
functions.  
1. Set the value for the following registry to “1.” (The default value is  
“0.”)  
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\W32Time\Parameters\LocalNTP  
Registry editing is a highly risky operation.  
Safety measures should be taken beforehand, e.g. creating  
registry backups. JVC shall not be held liable for any loss caused  
by registry editing.  
2. Restart the Windows Time Service.  
This can be done by opening [Administrative Tools] in [Control Panel]  
and selecting [Services], [Windows Time] and [Windows Time  
Properties].  
<Apply> button  
When the FTP operation is enabled, clicking this button  
starts the FTP operation with the settings made in this  
window.  
When the FTP operation is disabled, clicking this button  
does not save the settings made in this window.  
26  
 
LINK OF VN-C30U IMAGES  
Pasting VN-C30U output images on separately created web pages  
Images (still and moving images) captured using the VN-C30U can be  
incorporated and displayed on web pages created by the user.  
CAUTION  
• Images cannot be displayed when the VN-C30U unit is in the MPEG  
mode.  
• When the “HTTP Viewing” is set to “Disable” using the Setup Tool, it will  
not be possible to display images.  
Displaying a Still Image :  
Create a web page including the following description to display the still  
image in the web page.  
<IMG SRC=”http:// ****** /still.jpg”>  
(****: URL indicating the VN-C30U)  
Displaying a Moving Image :  
A moving image can either be a Serverpush image or a Java image.  
The image type should be selected according to the compatibility conditions  
of the web browser (or by adjusting the web page.)  
Display by Serverpush image  
Create a web page including the following description to display the moving  
image in the web page of a Serverpush-compatible web browser (i.e.  
Netscape).  
<IMG SRC=”http:// ****** /push.jpg”>  
(****: URL indicating the VN-C30U)  
27  
 
Display of a Java applet image  
Create a web page including the following description to display a moving  
image in the web page of a Java-compatible web browser (i.e. Internet  
Explorer, etc.).  
<APPLET CODE=”mjpeg.class”WIDTH=640 HEIGHT=480  
CodeBase=”http:// ****** /”> </APPLET>  
(****: URL indicating the VN-C30U)  
CAUTION  
• Both the displayed still images and moving images are displayed in the  
image sizes and compression rates set in the configuration.  
If the web browser is set to disable Java execution, images may not be  
displayed correctly.  
• If passwords are set, Java moving images cannot be displayed unless it  
has previously been authenticated. (Restriction with Internet Explorer)  
• The values of “WIDTH” and “HEIGHT” should be identical to those set in  
the image size setting of the VN-C30U.  
However, both “160 x 112” and “160 x 120” are valid.  
CAUTION  
• If the browser in use is Netscape Ver. 4.06 or older, it is required to  
update the Java Plug-in to Ver. 1.1 or higher in order to browse and  
display moving images.  
getjava/, etc.  
• Under certain environments, image reloading may be repeated when  
the [Pan/Tilt/Zoom] control window is displayed. This is not a  
malfunction, however.  
• When the [Time Stamp Format] file name is selected in the [FTP Client  
Configuration] window, a time stamp name for 1900’s (years) is used  
unless the correct time has been acquired from an NTP server.  
28  
 
Link Methods for Various Java  
Applets  
Since the Java applets listed below are used to run the functions in this unit’s  
factory-set web page, it is possible to easily incorporate them into your original  
HTML pages (*1).  
Pan/Tilt/Zoom Button  
Position Button  
Current Location Display  
(Control.class)  
(MemoryPositions.class)  
(Location.class)  
...  
Requires a basic knowledge of HTML.  
*
1
[Applet Common Coding] (Example when 192.168.0.2 is IP address of this machine)  
<APPLET CODE=”XXXXX.class” WIDTH=”XXX” HEIGHT=”XXX”  
codebase=”http://192.168.0.2/”>  
<PARAM NAME=”AAAAA” VALUE=”LLLLL”>  
<PARAM NAME=”BBBBB” VALUE=”MMMMM”>  
</APPLET>  
Note: Parts like XXXXX.class and AAAAA will change according to the actual  
applet being used.  
[Parameter Descriptions]  
5 Pan/Tilt/Zoom Button (Control.class) — Applet to control Pan/Tilt/Zoom  
movement of camera.  
Parameter name  
Description  
Default setting  
Gray  
bgcolor  
Sets background color in  
16-step 24-bit color  
cache  
Cache Prohibited/Allowed setting  
1[Prohibited] or 0 [Allowed]  
1[Prohibited]  
29  
 
[Parameter Descriptions]  
5 Position Button (MemoryPositions.class) — Applet to move camera position  
to the preset position.  
Parameter name  
Description  
Default setting  
bgcolor  
Sets background color in  
16-step 24-bit color  
Gray  
timer  
Memory position sampling cycle  
(10-step integer, millisecond  
specification)  
60000 msec  
1[Prohibited]  
cache  
Cache Prohibited/Allowed setting  
1[Prohibited] or 0 [Allowed]  
5 Current Location Display (Location.class) — Displays the current Pan/  
Tilt/Zoom position of the unit.  
Parameter name  
Description  
Default setting  
fgcolor  
Sets character color in 16-step  
24-bit color  
Green  
bgcolor  
timer  
Sets background color in 16-step  
24-bit color  
Black  
2 s  
Current position sampling cycle  
(10-step integer, second  
specification)  
30  
 
Regarding HTTP Port Change  
Function  
This version has been equipped with an HTTP Port change function. The  
port can be checked/selected using the provided Setup tool, in addition to  
via web browser.  
If you forget the HTTP Port number and cannot connect using a web browser,  
perform the following steps.  
[PROCEDURE]  
Input the IP address in the Setup tool, and check the “HTTP Port” while  
connected to the VN-C30U. Since the current port number is displayed, input  
the port number you want to change it to and click the OK button. (When the  
port number is changed, the system is automatically rebooted.)  
CAUTION  
If the connected VN-C30U is below Version 3.0, the HTTP Port cannot  
be changed.  
31  
 
VICTOR COMPANY OF JAPAN, LIMITED  
Printed in Japan  
LWT0031-001D  
is a registered trademark owned by VICTOR COMPANY OF JAPAN, LTD.  
is a registered trademark in Japan, the U.S.A., the U.K. and many other countries.  
C
COPYRIGHT 2002 VICTOR COMPANY OF JAPAN, LTD.  
 

Indesit Ventilation Hood LI178D User Manual
JBL Professional Home Theater System WEM 1 User Manual
Johnson Controls Air Conditioner 813196 UUM A 0112 User Manual
JVC VCR HR J245EK User Manual
Kenwood Car Video System DDX9702S User Manual
Kenwood CD Player KDC XBT8013U User Manual
Kenwood Food Processor FP110 series User Manual
Kenwood Speaker KSC SW10 User Manual
King Canada Planer KC 426C User Manual
KitchenAid Trimmer KEBI100B User Manual