Introduction  
Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been  
providing a world of unique, creative, and affordable solutions to the vast  
range of problems that confront video, audio, presentation, and broadcasting  
professionals on a daily basis. In recent years, we have redesigned and  
upgraded most of our line, making the best even better!  
Our 1,000-plus different models now appear in 11 groups1 that are clearly  
defined by function.  
Thank you for purchasing the FC-50 RS-232 Range Extender, which is  
ideal for controlling a single matrix switcher or other controllable device  
from long distance.  
The package includes the following items:  
One FC-50 RS-232 Range Extender unit  
Power supply (12V DC)  
This user manual2  
2
Getting Started  
We recommend that you:  
Unpack the equipment carefully and save the original box and  
packaging materials for possible future shipment  
Review the contents of this user manual  
Use Kramer high-performance high-resolution cables3  
1
GROUP 1: Distribution Amplifiers; GROUP 2: Switchers and Routers; GROUP 3: Control Systems; GROUP 4:  
Format/Standards Converters; GROUP 5: Range Extenders and Repeaters; GROUP 6: Specialty AV Products; GROUP 7:  
Scan Converters and Scalers; GROUP 8: Cables and Connectors; GROUP 9: Room Connectivity; GROUP 10: Accessories  
and Rack Adapters and GROUP 11: Sierra Video Products  
2 Download up-to-date Kramer user manuals from our Web site at http://www.kramerelectronics.com  
1
 
         
Getting Started  
2.1 Quick Start  
This quick start chart summarizes the basic setup and operation steps.  
KRAMER: SIMPLE CREATIVE TECHNOLOGY  
2
 
 
Overview  
3
Overview  
The high-quality Kramer MultiTOOLS FC-50 RS-232 Range Extender can  
connect either to a PC or to a device (for example, a switcher). By  
connecting two units (purchased separately) via a CAT 5 cable, the PC can  
control the switcher over a range of up to 1000 meters (3300 feet).  
In particular, the FC-50 features:  
Bidirectional RS-232 operation  
The Power Connect feature  
A CONNECTION switch to select between a crossed and a straight  
connection  
A PC/DEVICE pushbutton that is pressed or released if a device or a  
PC, respectively, are connected to the RS-232 port  
12V DC power  
3.1 About the Power Connect Feature  
The Power Connect feature applies as long as the cable can carry power.  
This feature is available when using STP cable and the distance does not  
exceed 50m (164ft) on standard CAT 5 cable. For longer distances, heavier  
gauge cable should be used (TP cable is still suitable for the video/audio  
transmission, but not for feeding the power at these distances). For units  
which are connected via RJ-45 connectors, make sure that the shield of the  
STP cable is connected to the metal casing of the connectors on both ends  
of the cable. For units which are connected via terminal block connectors,  
the shield of the STP cable must be connected to a ground terminal on the  
units at both ends (use the ground terminal of the power supply connection  
if necessary).  
For a TP cable exceeding a distance of 50m, separate power supplies should  
be connected to the transmitter and to the receiver simultaneously.  
3.2 Shielded Twisted Pair (STP) / Unshielded Twisted Pair (UTP)  
We recommend that you use Shielded Twisted Pair (STP) cable, and stress  
that the compliance to electromagnetic interference was tested using STP  
cable. There are different levels of STP cable available, and we advise you  
to use the best quality STP cable that you can afford. Our non-skew-free  
cable, Kramer BC-STP is intended for analog signals where skewing is not  
an issue.  
In cases where there is skewing, our Unshielded Twisted Pair (UTP) skew-  
free cable, Kramer BC-XTP, may be advantageous, and UTP cable might  
3
 
     
Your FC-50 RS-232 Range Extender  
also be preferable for long range applications. In any event when using UTP  
cable, it is advisable to ensure that the cable is installed far away from  
electric cables, motors and so on, which are prone to create electrical  
interference.  
3.3 Recommendations for Achieving the Best Performance  
To achieve the best performance:  
Use only good quality connection cables1 to avoid interference,  
deterioration in signal quality due to poor matching, and elevated noise  
levels (often associated with low quality cables).  
Do not secure the cables in tight bundles or roll the slack into tight coils  
Avoid interference from neighboring electrical appliances that may  
adversely influence signal quality and position your Kramer FC-50  
away from moisture, excessive sunlight and dust  
4
Your FC-50 RS-232 Range Extender  
Figure 1 and Table 1 define the FC-50 RS-232 Range Extender:  
Figure 1: FC-50 RS-232 Range Extender  
1 Available from Kramer Electronics on our Web site at http://www.kramerelectronics.com  
KRAMER: SIMPLE CREATIVE TECHNOLOGY  
4
 
       
Your FC-50 RS-232 Range Extender  
Table 1: FC-50 RS-232 Range Extender Features  
#
Feature  
Function  
1
2
3
12V DC  
+12V DC connector for powering the unit  
CAT 5 RJ-45 Connector  
Connect to1 the CAT 5 RJ-45 connector on the other FC-50 unit  
PC / DEVICE Button  
Press when a device is connected to the RS-232 port  
Release when a PC is connected to the RS-232 port  
RS-232 9-pin D-sub  
Connector  
Connects to either a PC or a device  
PINs 2, 3 and 5 are passed through the device  
4
5
GREEN=PC  
RED=DEVICE  
Lights in green when the PC/DEVICE button is released and in red  
when the PC/DEVICE button is pressed  
LED  
Figure 2 and Table 2 define the FC-50 underside:  
Table 2: FC-50 RS-232 Range Extender Underside Features  
Feature  
Function  
CROSSED /  
STRAIGHT  
Set to CROSSED for a crossed wire  
connection2 between the RS-232 port and the  
CONNECTION Switch PC/device  
Set to STRAGHT for a straight wire  
connection between the RS-232 port and the  
PC/device  
Figure 2: FC-50 RS-232  
Range Extender Underside  
1 Using a UTP CAT 5 cable with RJ-45 connectors at both ends (the PINOUT is defined in Table 3 and Figure 4)  
2 PINs 2 and 3 (Rx and Tx) are crossed in the wiring between the 9-pin D-sub connectors  
5
 
         
Connecting the FC-50 RS-232 Range Extender  
5
Connecting the FC-50 RS-232 Range Extender  
To connect two FC-50 units, as illustrated in the example in Figure 3, do  
the following:  
1. Connect a PC to the RS-232 port of the first FC-50 unit and release the  
PC/DEVICE button.  
2. Connect the RS-232 port of the second FC-50 unit to a device (for example,  
a switcher) and push in the PC/DEVICE button.  
3. Connect the CAT 5 RJ-45 connector of the first unit to the CAT 5 RJ-45  
connector of the second FC-50 unit via UTP cabling.  
4. Set the CONNECTION switch independently on both units as follows:  
.
STRAIGHT for a straight wire connection1 between  
the RS-232 port and the PC/device  
CROSSED for a crossed wire connection2 between  
the RS-232 port and the PC/device  
.
5. Connect the 12V DC power adapter to the power socket on the FC-50 and  
connect the adapter to the mains electricity (not illustrated in Figure 3).  
Figure 3: Connecting the FC-50 RS-232 Range Extender  
1 For example, flat cable  
2 Null modem  
KRAMER: SIMPLE CREATIVE TECHNOLOGY  
6
 
       
Connecting the FC-50 RS-232 Range Extender  
5.1 Wiring the CAT 5 LINE IN / LINE OUT RJ-45 Connectors  
Table 3 and Figure 4 define the UTP CAT 5 PINOUT, using a straight pin  
to pin cable with RJ-45 connectors:  
Table 3: CAT 5 PINOUT  
Figure 4: CAT 5 PINOUT  
EIA /TIA 568B  
PIN  
Wire Color  
Orange / White  
Orange  
1
2
3
4
5
6
7
8
Green / White  
Blue  
Blue / White  
Green  
Brown / White  
Brown  
7
 
       
Technical Specifications  
6
Technical Specifications  
The FC-50 technical specifications are shown in Table 4:  
Table 4: Technical Specifications1 of the FC-50  
PORTS:  
RS-232 on a 9-pin D-sub connector2, 1 CAT 5 RJ-45 connector  
BAUD RATES:  
DISPLAY:  
Up to 115.2kbaud  
GREEN=PC/RED=DEVICE LED  
OPERATING TEMPERATURE: 0° to +55°C (32° to 131°F)  
STORAGE TEMPERATURE:  
HUMIDITY:  
-45° to +72°C (-49° to 162°F)  
10% to 90%, RHL non-condensing  
5.32cm x 7.25cm x 4.2cm (2.09" x 2.85" x 1.65"), W, D, H  
12V DC, 42mA  
DIMENSIONS:  
POWER SOURCE:  
WEIGHT:  
0.3kg (0.67lbs) approx.  
1 Specifications are subject to change without notice  
2 Only PINs 2, 3, 5 on the RS-232 cable are valid  
KRAMER: SIMPLE CREATIVE TECHNOLOGY  
8
 
       
9
 
For the latest information on our products and a list of Kramer  
distributors, visit our Web site: www.kramerelectronics.com  
where updates to this user manual may be found.  
We welcome your questions, comments and feedback.  
Safety Warning:  
Disconnect the unit from the power supply before  
opening/servicing.  
Caution  
P/N: 2900-000333  
Rev:  
6
Kramer Electronics, Ltd.  
P/N: 2900-000333 REV 6  
 

Indesit Dishwasher DI 450 User Manual
Insignia Stereo Receiver NS R5100 User Manual
Insignia TV Mount 09 0878 User Manual
Intel Computer Accessories 05 2342 002 User Manual
Intel Computer Hardware UPI C42 User Manual
Intel Webcam IQ80321 User Manual
Invacare Mobility Aid Nutron R50LX User Manual
ITT Water Pump IM213 User Manual
Jensen GPS Receiver NL400W User Manual
Klipsch Speaker POWERED SUBWOOFERS User Manual