SIM100
Switch Indicator Module
User’s Manual
Revision 1.0
Copyright © 2008 Maretron, LLP All Rights Reserved
Maretron, LLP
9014 N. 23rd Ave #10
Phoenix, AZ 85021-7850
Maretron Manual Part #: M001801
Revision 1.0
Page i
®
Table of Contents
1 Introduction ...........................................................................................................................1
1.1 Firmware Revision.................................................................................................... 1
1.2 SIM100 Features...................................................................................................... 1
1.3 Quick Install.............................................................................................................. 2
2 Installation.............................................................................................................................2
2.1 Unpacking the Box ................................................................................................... 2
2.2 Choosing a Mounting Location................................................................................. 2
2.3 Mounting the SIM100 ............................................................................................... 3
2.4 Connecting the SIM100............................................................................................ 3
2.4.1 NMEA 2000® Connection............................................................................... 3
2.4.2 Switch Connections ....................................................................................... 4
2.4.3 Checking Connections................................................................................... 6
2.5 Configuring the SIM100............................................................................................ 6
2.5.1 Device Instance ............................................................................................. 6
2.5.2 Channel #1 Mode .......................................................................................... 6
2.5.3 Channel #2 Mode .......................................................................................... 6
2.5.4 Channel #3 Mode .......................................................................................... 6
2.5.5 Channel #4 Mode .......................................................................................... 6
2.5.6 Channel #5 Mode .......................................................................................... 6
2.5.7 Channel #6 Mode .......................................................................................... 6
2.5.8 Advanced Configuration…............................................................................. 7
2.5.9 NMEA 2000® PGN Enable/Disable................................................................ 7
2.5.10 Restore Factory Defaults............................................................................... 7
4 Troubleshooting ....................................................................................................................7
5 Technical Specifications........................................................................................................9
6 Technical Support ...............................................................................................................10
7 Installation Template ...........................................................................................................11
8 Maretron (2 Year) Limited Warranty....................................................................................12
Table of Figures
Figure 2 – NMEA 2000® Connector Face Views ....................................................................... 4
Figure 3 – Switch With End of Line Resistor Connection Diagram............................................ 5
Figure 4 – Switch Without End of Line Resistor Connection Diagram....................................... 5
Table of Appendices
Appendix A – NMEA 2000® Interfacing.................................................................................... A1
Revision 1.0
Page iii
®
1 Introduction
Congratulations on your purchase of the Maretron Switch Indicator Module. Maretron has
designed and built your SIM100 to the highest standards for years of dependable and accurate
service.
Maretron’s Switch Indicator Module monitors switch closure devices including, but not limited
to, safety equipment (e.g., heat, smoke, carbon monoxide, explosive vapor detectors), security
systems (e.g., motion, vibration, glass break, door and port hole magnetic switches), and
vessel monitoring equipment (e.g., valve closed/open, high water bilge). The SIM100
continually monitors these switch closure devices and broadcasts information over the NMEA
2000 network about the switch state so the crew can be alerted to potential conditions or
problems that warrant further investigation. Advanced features of the SIM100 include the
ability to detect whether or not power has been disconnected from the monitored device or if
the signal wires have been disconnected due to either corrosion, tampering, or for any other
reason (if the monitored device is so equipped). With the SIM100, you can rest assured that
critical sensors are receiving power, signal wires are connected, and all the safety, security
and vessel functions are under constant supervision.
The Maretron SIM100 is designed to operate within the harsh demands of the marine
environment. However, no piece of marine electronic equipment can function properly unless
installed, configured, and maintained in the correct manner. Please read carefully and follow
these instructions for installation, configuration, and usage of the Maretron SIM100 in order to
ensure optimal performance.
1.1 Firmware Revision
This manual corresponds to SIM100 firmware revision 1.0.0.
1.2 SIM100 Features
The Maretron SIM100 has the following features.
• NMEA 2000® Interface
• Waterproof Connectors
• Sealed Waterproof Enclosure
• Opto-Isolated from NMEA 2000® Eliminating Potential Ground Loops
•
•
•
Monitors and reports switch status
Can detect and report problems like opens and shorts in switch circuits
Compatible with Maretron-Supplied
o
o
o
o
Heat Detectors
Smoke Detectors
Carbon Monoxide Detectors
Bilge Water Detectors
• Also Compatible With
o
o
o
Magnetic Switches
Glass Break Detectors
Door, Hatch, and Porthole Magnetic Switches
Revision 1.0
Page 1
SIM100 User's Manual
1.3 SIM100 Accessories
Maretron offers the following accessories for the SIM100:
• SH-499CSTE
• CO1000-S-W
• LP1000-S-W
• BHW100
• MD-6157-N
• MS-1035
• MS-1085-N
• MS-1055-N
• MS-1075
Smoke/Heat Detector
Carbon Monoxide (CO) Detector (Surface Mount White)
Liquid Petroleum (LP) Detector (Surface Mount White)
Bilge High Water Detector
Motion Detector
Magnetic Switch Rectangular (Indoor)
Magnetic Switch Rectangular (Outdoor)
Magnetic Switch Cylinder (Indoor/Outdoor)
Magnetic Switch Recessed (Indoor/Outdoor)
1.4 Quick Install
Installing the Maretron SIM100 involves the following five steps. Please refer to the individual
sections for additional details.
2 Installation
2.1 Unpacking the Box
When unpacking the box containing the Maretron SIM100, you should find the following items:
1 – SIM100 – Switch Indicator Module
1 – Parts Bag containing 4 Stainless Steel Mounting Screws
1 – SIM100 User’s Manual
1 – Warranty Registration Card
If any of these items are missing or damaged, please contact Maretron.
2.2 Choosing a Mounting Location
Please consider the following when choosing a mounting location.
1. The SIM100 is waterproof, so it can be mounted in a damp or dry location.
2. The orientation is not important, so the SIM100 can be mounted on a horizontal deck,
vertical bulkhead, or upside down if desired.
3. The SIM100 is temperature-rated to 55°C (130°F), so it should be mounted away from
engines or engine rooms where the operating temperature exceeds the specified limit.
Page 2
Revision 1.0
®
2.3 Mounting the SIM100
Attach the SIM100 securely to the vessel using the included stainless steel mounting screws or
Figure 1 – Mounting the SIM100
2.4 Connecting the SIM100
The SIM100 requires two types of electrical connections: 1) the NMEA 2000® connection (refer
2.4.1 NMEA 2000® Connection
The NMEA 2000® connector can be found on the side of the enclosure. The NMEA 2000®
NMEA 2000® network using a Maretron NMEA 2000® cable (or compatible cable) by
connecting the female end of the cable to the SIM100 (note the key on the male connector and
keyway on the female connector). Be sure the cable is connected securely and that the collar
on the cable connector is tightened firmly. Connect the other end of the cable (male) to the
NMEA 2000® network in the same manner. The SIM100 is designed such that you can plug or
unplug it from an NMEA 2000® network while the power to the network is connected or
disconnected. Please follow recommended practices for installing NMEA 2000® network
products.
Revision 1.0
Page 3
SIM100 User's Manual
Figure 2 – NMEA 2000® Connector Face Views
2.4.2 Switch Connections
The SIM100 switch connections are made by connecting to the 12-pin terminal strip on the top
of the unit. First, remove the four screws at the corners of the unit detaching the splash guard
from the unit. On the bottom of the splash guard, you will find a label detailing the wire
connection to pin number assignments, which are repeated in the table below.
Pin #
1
Signal Name
SW1A
SW1B
SW2A
SW2Bl
SW3Al
SW3B
SW4A
SW4B
SW5A
SW5B
SW6A
SW6B
Connection
Switch #1 Signal A
Switch #1 Signal B
Switch #2 Signal A
Switch #2 Signal B
Switch #3 Signal A
Switch #3 Signal B
Switch #4 Signal A
Switch #4 Signal B
Switch #5 Signal A
Switch #5 Signal B
Switch #6 Signal A
Switch #6 Signal B
2
3
4
5
6
7
8
9
10
11
12
Before attempting to connect the SIM100 to the AC source, determine the type of system you
will be monitoring. The SIM100 supports the connection and monitoring of two different system
types; 1) switch with end-of-line resistor (Section 2.4.2.1), or 2) switch without end-of-line
resistor (Section 2.4.2.2). To connect Maretron SIM100 accessories, please refer to the
installation directions that accompany each accessory.
Page 4
Revision 1.0
®
2.4.2.1 Switch With End of Line Resistor
Please refer to Figure 3 for connecting the SIM100 to a switch with an end of line resistor.
This figure shows the connection of the monitored switch to switch channel 1 via the terminals
named SW1A and SW1B. Connections to other switch terminals are similar.
8 KΩ end-of-
Monitored switch
line resistor
SIM100 Screw Terminals
1
2
3
4
5
6
7
8
9 10 11 12
Figure 3 – Switch With End of Line Resistor Connection Diagram
2.4.2.2 Switch Without End of Line Resistor
Please refer to Figure 4 for connecting the SIM100 to a switch without an end of line resistor.
This figure shows the connection of the monitored switch to switch channel 1 via the terminals
named SW1A and SW1B. Connections to other switch terminals are similar.
Monitored switch
SIM100 Screw Terminals
1
2
3
4
5
6
7
8
9 10 11 12
Figure 4 – Switch Without End of Line Resistor Connection Diagram
Revision 1.0
Page 5
SIM100 User's Manual
2.4.3 Checking Connections
Once the NMEA 2000® connection and switch connection(s) to the SIM100 have been
completed, check to see that information is being properly transmitted by observing an
“Troubleshooting”.
2.5 Configuring the SIM100
The SIM100 will transmit data over the NMEA 2000 network as it is shipped from the factory;
however, it may require configuration, depending on the type of switch monitored. There are
several configurable items within the SIM100, which are detailed in the remainder of this
section.
You configure the SIM100 using a Maretron DSM250 display or other NMEA 2000® display
unit that is capable of configuring the SIM100. Please refer to the Maretron DSM250 User’s
Manual for details.
2.5.1 Device Instance
NMEA 2000® provides a unique device instance for each switch monitoring device on a vessel.
This value should be programmed in each SIM100 so that each SIM100 is associated with a
unique device instance number. The default instance number is 0, which is used to indicate the
first SIM100 that is hooked to the network. Subsequent SIM100s connected to the network
would be numbered 1, 2, and so on.
2.5.2 Channel #1 Mode
2.5.3 Channel #2 Mode
2.5.4 Channel #3 Mode
2.5.5 Channel #4 Mode
2.5.6 Channel #5 Mode
2.5.7 Channel #6 Mode
You must configure the SIM100 as to what type of switch circuit it is monitoring. The allowable
values for this parameter are as follows:
• “End of Line Resistor” (default) – The switch circuit has a SPST switch connecting the A
and B terminals, with a parallel 8 KΩ end-of-line resistor. This allows the SIM100 to
monitor the circuit and indicate an error condition if the monitored circuit somehow
becomes disconnected from the terminals on the SIM100.
• “No End of Line Resistor” – The switch circuit has a SPST switch connecting the A and
B terminals, with a no parallel end-of-line resistor. The SIM100 is not able to monitor the
circuit for disconnection in this case.
• “Disable” – Use this value if no switch circuit is connected to the corresponding switch
terminals. The SIM100 will indicate that no data is available for this circuit.
Page 6
Revision 1.0
®
2.5.8 Advanced Configuration…
Certain parameters do not normally need to be set in order for normal operation, but are
included in an advanced configuration section for use in special situations.
2.5.9 NMEA 2000® PGN Enable/Disable
The SIM100 is capable of transmitting NMEA 2000® messages (or PGNs) associated with
monitored switch circuits. You may individually enable or disable each of these messages. You
may also change the rate of transmission of each of these messages if desired.
2.5.10 Restore Factory Defaults
Selecting this configuration option causes all stored parameters in the SIM100 to be reset to
the values they contained when the unit was manufactured.
3 Maintenance
Regular maintenance is important to ensure continued proper operation of the Maretron
SIM100. Perform the following tasks periodically:
• Clean the unit with a soft cloth. Do not use chemical cleaners as they may remove
paint or markings or may corrode the SIM100 enclosure or seals.
• Ensure that the unit is mounted securely and cannot be moved relative to the mounting
surface. If the unit is loose, tighten the mounting screws.
• Check the security of the cable connected to the NMEA 2000® connector, and tighten if
necessary.
• Check the security of all of the switch connections on the top of the unit and tighten if
necessary.
4 Troubleshooting
If you notice unexpected operation of the Maretron SIM100, follow the troubleshooting
procedures in this section to remedy simple problems. If these steps do not solve your
information).
Symptom
Troubleshooting Procedure
No switch indicator data Ensure that the SIM100 is properly connected to the NMEA 2000®
visible on NMEA 2000®
network.
network.
Ensure that the switches are properly connected to the SIM100.
Ensure that each indicator that you wish to monitor is not
configured as “Disabled”.
Ensure that the SIM100 has the appropriate NMEA 2000® PGNs
Revision 1.0
Page 7
SIM100 User's Manual
A switch indicator
Ensure that there is not a short circuit in the wiring for the switch.
always reads “Closed”
Measure the resistance between the “A” and “B” terminals for the
appropriate indicator. If the switch is open, the resistance should
either be an open-circuit, if the indicator is configured as “No End
of Line Resistor”, or should measure 8 KΩ if the indicator is
configured as “End of Line Resistor”. If the switch is closed, the
resistance should be close to 0 Ω.
A switch indicator
always reads “Error”
Ensure that the configuration of the indicator matches the circuit
connected to it. Measure the resistance between the “A” and “B”
terminals for the appropriate indicator. If the switch is open, the
resistance should either be an open-circuit, if the indicator is
configured as “No End of Line Resistor”, or should measure 8 KΩ if
the indicator is configured as “End of Line Resistor”. If the switch
is closed, the resistance should be close to 0 Ω.
A switch indicator
always reads “Open”
Ensure that the switch is connected to the indicator terminals that
that there are no open circuits between the SIM100 and the switch.
Measure the resistance between the “A” and “B” terminals for the
appropriate indicator. If the switch is open, the resistance should
either be an open-circuit, if the indicator is configured as “No End
of Line Resistor”, or should measure 8 KΩ if the indicator is
configured as “End of Line Resistor”. If the switch is closed, the
resistance should be close to 0 Ω.
Page 8
Revision 1.0
®
5 Technical Specifications
As Maretron is constantly improving its products, all specifications are subject to change
without notice. Maretron products are designed to be accurate and reliable; however, they
should be used only as aids to navigation and not as a replacement for traditional navigation
aids and techniques.
Specifications
Parameter
Value
Comment
End of Line Resistor
8 KΩ ± 5%
Included with Maretron-supplied sensors
Certifications
Parameter
Comment
NMEA 2000® Standard
Level A
Maritime Navigation and Radiocommunication Equipment & Systems
Maritime Navigation and Radiocommunication Equipment & Systems
FCC and CE Mark
IEC 61162-3
IEC 60945
Electromagnetic Compatibility
NMEA 2000® Parameter Group Numbers (PGNs)
Description
PGN #
PGN Name
Default Rate
Periodic Data PGNs
127501 Binary Switch Bank Status
1 time/15 seconds and
on switch change
Response to Requested PGNs 126464 PGN List (Transmit and Receive)
126996 Product Information
N/A
N/A
N/A
N/A
N/A
N/A
N/A
126998 Configuration Information
Protocol PGNs
059392 ISO Acknowledge
059904 ISO Request
060928 ISO Address Claim
065240 ISO Address Command
126208 NMEA Request/Command/Acknowledge
126720 Configuration
N/A
N/A
Maretron Proprietary PGNs
Electrical
Parameter
Value
Comment
Operating Voltage
9 to 32 Volts
DC Voltage
Power Consumption
Load Equivalence Number (LEN)
Reverse Battery Protection
Load Dump Protection
100 mA
2
Yes
Yes
NMEA 2000® Interface
NMEA 2000® Spec. (1LEN = 50 mA)
Indefinitely
Energy Rated per SAE J1113
Mechanical
Parameter
Size
Value
Comment
Including Flanges for Mounting
3.50” x 4.20” x 2.03”
(88.9mm x 106.7mm x 51.6mm)
13 oz. (368.5 g)
Weight
Revision 1.0
Page 9
SIM100 User's Manual
6 Technical Support
If you require technical support for Maretron products, you can reach us in any of the following
ways:
Telephone: 1-866-550-9100
Fax: 1-602-861-1777
E-mail: [email protected]
Mail: Maretron, LLC
Attn: Technical Support
9014 N. 23rd Ave Suite 10
Phoenix, AZ 85021 USA
Page 10
Revision 1.0
SIM100 User's Manual
8 Maretron (2 Year) Limited Warranty
Maretron warrants the SIM100 to be free from defects in materials and workmanship for two (2) years from the
date of original purchase. If within the applicable period any such products shall be proved to Maretron’s
satisfaction to fail to meet the above limited warranty, such products shall be repaired or replaced at Maretron’s
option. Purchaser's exclusive remedy and Maretron’s sole obligation hereunder, provided product is returned
pursuant to the return requirements below, shall be limited to the repair or replacement, at Maretron’s option, of
any product not meeting the above limited warranty and which is returned to Maretron; or if Maretron is unable to
deliver a replacement that is free from defects in materials or workmanship, Purchaser’s payment for such
product will be refunded. Maretron assumes no liability whatsoever for expenses of removing any defective
product or part or for installing the repaired product or part or a replacement therefore or for any loss or damage
to equipment in connection with which Maretron’s products or parts shall be used. With respect to products not
manufactured by Maretron, Maretron’s warranty obligation shall in all respects conform to and be limited to the
warranty actually extended to Maretron by its supplier. The foregoing warranties shall not apply with respect to
products subjected to negligence, misuse, misapplication, accident, damages by circumstances beyond
Maretron’s control, to improper installation, operation, maintenance, or storage, or to other than normal use or
service.
THE FOREGOING WARRANTIES ARE EXPRESSLY IN LIEU OF AND EXCLUDES ALL OTHER EXPRESS OR
IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE.
Statements made by any person, including representatives of Maretron, which are inconsistent or in conflict with
the terms of this Limited Warranty, shall not be binding upon Maretron unless reduced to writing and approved by
an officer of Maretron.
IN NO CASE WILL MARETRON BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, DAMAGES
FOR LOSS OF USE, LOSS OF ANTICIPATED PROFITS OR SAVINGS, OR ANY OTHER LOSS INCURRED
BECAUSE OF INTERRUPTION OF SERVICE. IN NO EVENT SHALL MARETRON’S AGGREGATE LIABILITY
EXCEED THE PURCHASE PRICE OF THE PRODUCT(S) INVOLVED. MARETRON SHALL NOT BE SUBJECT
TO ANY OTHER OBLIGATIONS OR LIABILITIES, WHETHER ARISING OUT OF BREACH OF CONTRACT OR
WARRANTY, TORT (INCLUDING NEGLIGENCE), OR OTHER THEORIES OF LAW WITH RESPECT TO
PRODUCTS SOLD OR SERVICES RENDERED BY MARETRON, OR ANY UNDERTAKINGS, ACTS OR
OMISSIONS RELATING THERETO.
Maretron does not warrant that the functions contained in any software programs or products will meet
purchaser’s requirements or that the operation of the software programs or products will be uninterrupted or error
free. Purchaser assumes responsibility for the selection of the software programs or products to achieve the
intended results, and for the installation, use and results obtained from said programs or products. No
specifications, samples, descriptions, or illustrations provided Maretron to Purchaser, whether directly, in trade
literature, brochures or other documentation shall be construed as warranties of any kind, and any failure to conform
with such specifications, samples, descriptions, or illustrations shall not constitute any breach of Maretron’s limited
warranty.
Warranty Return Procedure:
To apply for warranty claims, contact Maretron or one of its dealers to describe the problem and determine the
appropriate course of action. If a return is necessary, place the product in its original packaging together with
proof of purchase and send to an Authorized Maretron Service Location. You are responsible for all shipping and
insurance charges. Maretron will return the replaced or repaired product with all shipping and handling prepaid
except for requests requiring expedited shipping (i.e. overnight shipments). Failure to follow this warranty return
procedure could result in the product’s warranty becoming null and void.
Maretron reserves the right to modify or replace, at its sole discretion, without prior notification, the warranty listed
above. To obtain a copy of the then current warranty policy, please go to the following web page:
Page 12
Revision 1.0
®
Appendix A – NMEA 2000® Interfacing
SIM100 NMEA 2000® Periodic Data Transmitted PGNs
PGN 127501 – Binary Switch Bank Status
The SIM100 uses this PGN to transmit the state of each of the connected switch inputs
Field 1: Indicator Bank Instance – This field identifies the particular switch bank to which this
value of this field.
2: Indicator #1 – This field indicates the state of the switch connected to the SW1A and
SW1B inputs of the SIM100. The state will be one of the following values:
• “Closed” – The monitored switch is closed.
• “Open” – The monitored switch is open.
• “Error” – There is an open connection between the SIM100 and the monitored
switch. This state can occur only when the indicator is configured to use an
End of Line Resistor.
• “Data Not Available” – The indicator is configured as “Disabled”
3: Indicator #2 – This field indicates the state of the switch connected to the SW2A and
SW2B inputs of the SIM100.
4: Indicator #3 – This field indicates the state of the switch connected to the SW3A and
SW3B inputs of the SIM100.
5: Indicator #4 – This field indicates the state of the switch connected to the SW4A and
SW4B inputs of the SIM100.
6: Indicator #5 – This field indicates the state of the switch connected to the SW5A and
SW5B inputs of the SIM100.
7: Indicator #6 – This field indicates the state of the switch connected to the SW6A and
SW6B inputs of the SIM100.
Revision 1.0
Appendix A – NMEA 2000 Interfacing
Page A1
|