LVUN-600
Non-invasive Ultrasonic Point Level Switches
UNPACKING INSTRUCTIONS
UNPACKING INSTRUCTIONS
Remove the Packing List and verify that you have received all equipment, includ-
ing the following (quantities in parentheses):
Ultrasonic Level Switch (1)
Operator’s Manual (1)
If you have any questions about the shipment, please call the OMEGA Customer
Service Department. When you receive the shipment, inspect the container and
equipment for signs of damage. Note any evidence of rough handling in transit.
Immediately report any damage to the shipping agent.
Note:
The carrier will not honor damage claims unless all shipping
material is saved for inspection. After examining and removing
contents, save packing material and carton in the event reship-
ping is necessary.
For Ultrasonic Point Level Switches LVUN-600 Series
2
TABLE OF CONTENTS
Page
Chapter 1
Chapter 2
Chapter 3
Chapter 4
Chapter 5
Point Level Model Description . . . . . . . . . . . . . . . . . . . . . . . . . .4
Principles of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-7
System Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-9
Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-11
3
For Ultrasonic Point Level Switches LVUN-600Series
SYSTEM DESCRIPTIONS
1
GENERAL DESCRIPTION
The LVUN-600 Series Liquid Level Detection system is an ideal, low cost ultrasonic
liquid level detection system for many applications. It operates in a broad spec-
trum of viscous to light liquids.
PRINCIPLES OF OPERATION
2
PRINCIPLES OF OPERATION
The LVUN-600 Series operates using ultrasonic sound wave propagation. Ultrasonic
sound waves are greatly attenuated when transmitted through air. Conversely,
when liquid is present, transmission of the sound waves is greatly enhanced. The
electronic control unit, either integral or remote to the sensor, generates electrical
signals that are converted to bursts of ultrasonic energy at the sensor. The ultra-
sonic bursts are transmitted across the liquid sensing gap of the sensor. Upon
receipt of a valid signal at the receiver, the solid state electronics generate a “data
enable” condition indicating liquid is present. This signal energizes a relay and
provides an output condition.
4
For Ultrasonic Point Level Switches LVUN-600 Series
INSTALLATION
3
GENERAL INSTALLATION
All units are easy to install. The sensor with its remote electronic control unit can
be mounted in any position or orientation desired.
Make sure that all wiring, conduit and electrical fittings conform to local electrical
codes for the location selected.
VISUAL INSPECTION
Unpack the control unit and sensor assemblies. Visually inspect them for any
damage. Advise Cosense immediately if either assembly is damaged.
PRELIMINARY OPERATIONAL CHECK
Before installing the unit, a simple operational checkout should be performed as
follows:
WARNING: In a hazardous environment never open the housing cover or con-
nect the power leads without first disconnecting the electrical power at its
source.
1. Fill a container with liquid.
2. Open the control unit housing cover and connect the power to the control unit
(see wiring diagram).
3. Apply power from the source.
4. Place the sensor in the liquid. The relay should energize.
5. Remove the sensor from the liquid. The relay will de-energize indicating that
the system is functioning properly.
6. Disconnect the power to the control unit.
7. Proceed to final installation.
NON-INVASIVE / CLAMP-ON TIME
Refer to the typical installation diagram and follow the instructions below.
1. Clean the mounting surface of the pipe or vessel.
2. Coat the sensor faces and the area on the pipe or vessel where sensors are to
be mounted liberally with coupling compound (silicone grease or heat sink
compound).
3. Clamp the sensor assembly on the pipe or vessel. Tighten the clamp assembly
on the vessel until the sensor assembly is firmly mounted against the sensor
wall. Do not over tighten.
4. Run the cable to the control unit assembly.
For Ultrasonic Point Level Switches LVUN-600Series
5
INSTALLATION
3
CONTROL UNIT
Refer to the typical installation diagram and control unit dimensions when
installing the control unit.
CALIBRATION PROCEDURE
After the installation is complete, the system must be calibrated for proper opera-
tion.
1. Connect the sensor cable to electronics as shown in wiring diagram.
2. Connect power as per wiring diagram.
3. Turn the power on.
4. Allow the liquid to rise above the sensing point until the relay is energized.
5. Allow the liquid to fall below the sensing point, relay should de-energized.
6. Repeat steps 4 and 5.
7. Unit is now calibrated. When the liquid level is above the sensing point, the
relay will be energized. When the liquid level is below the sensing point,
the relay will be de-energized.
MAINTENANCE
PREVENTIVE MAINTENANCE
Electronics are constructed with solid state components.
Periodically, check and clean the sensor(s) when used with
liquids which cause a coating to build up on the sensor. No
other maintenance is required.
CLEANING
If the pipe or vessel to which the sensor is mounted is to be steam cleaned or
cleaned with abrasive detergents, remove the entire unit before cleaning by:
1. Disconnecting the power at source.
2. Opening the housing cover.
For Ultrasonic Point Level Switches LVUN-600 Series
6
INSTALLATION
3
3. Removing power and control wiring cables.
4. Unthreading the sensor.
To reinstall, follow Installation Procedure
SYSTEM MALFUNCTION
Should the system malfunction, notify OMEGA immediately
7
For Ultrasonic Point Level Switches LVUN-600 Series
SYSTEM WIRING DIAGRAM
4
WIRING DIAGRAM
Two Channel
For Ultrasonic Point Level Switches LVUN-600 Series
8
SYSTEM WIRING DIAGRAM
4
WIRING DIAGRAM
Multi Channel:
Four Channel:
Three Channel:
9
For Ultrasonic Point Level Switches LVUN-600 Series
DIMENSIONAL DRAWINGS
5
ENCLOSURE DIMENSIONS
For Ultrasonic Point Level Switches LVUN-600 Series
10
DIMENSIONAL DRAWINGS
5
TYPICAL APPLICATION
For Ultrasonic Point Level Switches LVUN-600 Series
11
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a
period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month
grace period to the normal one (1) year product warranty to cover handling and shipping time. This
ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service
Department will issue an Authorized Return (AR) number immediately upon phone or written request.
Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no
charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser,
including but not limited to mishandling, improper interfacing, operation outside of design limits,
improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of
having been tampered with or shows evidence of having been damaged as a result of excessive corrosion;
or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating
conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not
limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However,
OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any
damages that result from the use of its products in accordance with information provided by
OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the
company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR
REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF
TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF
LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of
OMEGA with respect to this order, whether based on contract, warranty, negligence,
indemnification, strict liability or otherwise, shall not exceed the purchase price of the
component upon which liability is based. In no event shall OMEGA be liable for
consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic
Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical
applications or used on humans. Should any Product(s) be used in or with any nuclear installation or
activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility
as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify
OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the
Product(s) in such a manner.
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE
RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN
(AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID
PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return
package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent
breakage in transit.
FOR WARRANTY RETURNS, please have the
following information available BEFORE
contacting OMEGA:
FOR NON-WARRANTY REPAIRS, consult OMEGA
for current repair charges. Have the following
information available BEFORE contacting OMEGA:
1. Purchase Order number under which the product
was PURCHASED,
1. Purchase Order number to cover the COST
of the repair,
2. Model and serial number of the product under
warranty, and
3. Repair instructions and/or specific problems
relative to the product.
2. Model and serial number of the product, and
3. Repair instructions and/or specific problems
relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords
our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2005 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the
prior written consent of OMEGA ENGINEERING, INC.
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGA…Of Course!
Shop online at omega.com
TEMPERATURE
Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies
Wire: Thermocouple, RTD & Thermistor
Calibrators & Ice Point References
Recorders, Controllers & Process Monitors
Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Transducers & Strain Gages
Load Cells & Pressure Gages
Displacement Transducers
Instrumentation & Accessories
FLOW/LEVEL
Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Rotameters, Gas Mass Flowmeters & Flow Computers
Air Velocity Indicators
Turbine/Paddlewheel Systems
Totalizers & Batch Controllers
pH/CONDUCTIVITY
Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ pH Electrodes, Testers & Accessories
Benchtop/Laboratory Meters
Controllers, Calibrators, Simulators & Pumps
Industrial pH & Conductivity Equipment
DATA ACQUISITION
Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Data Acquisition & Engineering Software
Communications-Based Acquisition Systems
Plug-in Cards for Apple, IBM & Compatibles
Datalogging Systems
Recorders, Printers & Plotters
HEATERS
Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Heating Cable
Cartridge & Strip Heaters
Immersion & Band Heaters
Flexible Heaters
Laboratory Heaters
ENVIRONMENTAL
MONITORING AND CONTROL
Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Metering & Control Instrumentation
Refractometers
Pumps & Tubing
Air, Soil & Water Monitors
Industrial Water & Wastewater Treatment
pH, Conductivity & Dissolved Oxygen Instruments
M-4201/1005
|