Gas Inserts
U32 Regency Gas Insert
U32 Regency Gas Insert
Model
U32-NG5
U32-LP5
Fuel Type
Natural Gas
5” W.C. (1.25 kPa)
3.8” W.C. (0.95 kPa)
1.1” W.C. (0.27 kPa)
#37 DMS
Propane
Minimum Supply Pressure
Manifold Pressure - High
Manifold Pressure - Low
Orifice Size -Altitude 0-4500 ft.
12” W.C. (2.99 kPa)
11” W.C. (2.74 kPa)
2.9” W.C. (0.72 kPa)
#52 DMS
Minimum Input
Altitude 0-4500 ft. (0-1372m)
15,300 BTU/h
(4.48 kW)
15,000 BTU/h
(4.40 kW)
Maximum Input
Altitude 0-4500 ft. (0-1372m)
30,000 BTU/h
(8.79 kW)
30,000 BTU/h
(8.79 kW)
Vent Sizing
3” Co-linear
3” Co-linear
Approved Venting Systems
Flex Vent Systems:
FPI AstroCap™ Flex Vent
A
Minimum Fireplace Dimensions
The minimum fireplace dimensions for the FPI gas fireplace insert are
shown in the following diagrams:
B
C
G
I
F
M
L
J
H D
E
K
N
Dimension Description
U32
A
B
C
D
E
F
G
H
I
Faceplate Width
Faceplate Height
Unit Width
40-1/4” (1022mm)
26-1/4” (667mm)
28” (711mm)
Contour
Molded
Dimension Description
Unit Height
20” (508mm)
Faceplate
Faceplate
Unit Depth
13-3/4” (349mm)
10-3/4” (273mm)
1-3/8” (35mm)
21-1/16” (535mm)
3-3/4” (95mm)
J
Height
22” (559mm)
26-1/2” (673mm)
14” (356mm)
22” (559mm)
29” (737mm)
15” (381mm)
10” (254mm)
22-1/2” (572mm)
Faceplate to Vent Centerline
Faceplate Depth
K
L
Width
Depth
M
N
Max. Lintel Bar Depth
Rear Width
9” (229mm)
Height to Vent Collar
22-1/2” (572mm)
Optional or Standard Front Depth
August 2008 Product Specifications Book
125
|