I N S T A L L A T I O N I N S T R U C T I O N S
Instrucciones de instalación
Installationsanleitung
Istruzioni di installazione
Installatie-instructies
Instruções de Instalação
Instructions d´installation
IN-WALL ACCESSORY BOX
Spanish Product Description
German Product Description
Portuguese Product Description
Italian Product Description
Dutch Product Description
French Product Description
PAC516
Installation Instructions
PAC516
DIMENSIONS
A
B
28.4
1.12
55.9
2.20
368.3
14.50
87
3.43
94.7
3.73
DETAIL A
SC ALE 1 : 1
393.7
15.50
44
1.734
28.2
1.109
8.3
0.33
22.2
0.875
31.8
1.25
DETAIL B
SC ALE 1 : 1
154.9
6.10
MEASUREMENTS: [MILLIMETERS]
INCHES
LEGEND
Tighten Fastener
Pencil Mark
Apretar elemento de fijación
Befestigungsteil festziehen
Apertar fixador
Marcar con lápiz
Stiftmarkierung
Marcar com lápis
Segno a matita
Potloodmerkteken
Marquage au crayon
Serrare il fissaggio
Bevestiging vastdraaien
Serrez les fixations
Loosen Fastener
Drill Hole
Aflojar elemento de fijación
Befestigungsteil lösen
Desapertar fixador
Perforar
Bohrloch
Fazer furo
Praticare un foro
Gat boren
Allentare il fissaggio
Bevestiging losdraaien
Desserrez les fixations
Percez un trou
Phillips Screwdriver
Hex-Head Wrench
Destornillador Phillips
Llave de cabeza hexagonal
Sechskantschlüssel
Chave de cabeça sextavada
Chiave esagonale
Kreuzschlitzschraubendreher
Chave de fendas Phillips
Cacciavite a stella
Kruiskopschroevendraaier
Tournevis à pointe cruciforme
Zeskantsleutel
Clé à tête hexagonale
3
PAC516
Installation Instructions
TOOLS REQUIRED FOR INSTALLATION
3/16"
M4
(included)
PARTS
Grounding screw and washer installed at factory
(See Figure 4 on page 6.)
J (2)
#10
H (2)
10-32 x 3/8"
Earthing symbol IEC 60418 No. 5019
affixed adjacent to grounding terminal.
A (1)
PAC516
1
B (4)
1/4"
C (6)
[Wire Tie Clip]
2
D (1)
M4
G (4)
1/4" x 2"
E (8)
1/8-18 x 3/4"
F (4)
M7 x 40mm
4
Installation Instructions
PAC516
INSTALLATION
The PAC516 is intended for use in installations where the wall
surface has not been finished and the structure (studs) is
exposed. The PAC516 requires the wall be finished around the
opening of the box after the box has been installed.
PAC516
Cut Out Area
WARNING: IMPROPER INSTALLATION CAN RESULT IN
DEATH OR SERIOUS PERSONAL INJURY! This accessory
should be installed by qualified personnel.
PAC-516 Site Preparation
Locate and Prepare Mounting Site
1. Identify a suitable wall location for the accessory.
IMPORTANT ! : The PAC516 is designed for in-wall
installation between two wood or steel studs, 16" on
center. Inadequate space will remain on each side
between studs for electrical wires/cables, plumbing,
ductwork, or insulation. Locate accordingly!
WARNING: ELECTRICAL SHOCK HAZARD! CUTTING
OR DRILLING INTO ELECTRICAL WIRES OR CABLES
CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY!
ALWAYS make certain area behind mounting surfaces is free
of electrical wires and cables before cutting, drilling, or
installing fasteners.
Figure 1
Accessory Box Installation
WARNING: EXPLOSION AND FIRE HAZARD! CUTTING
OR DRILLING INTO GAS PLUMBING CAN CAUSE DEATH
OR SERIOUS PERSONAL INJURY! ALWAYS make certain
area behind mounting surfaces is free of gas, water, waste, or
any other plumbing before cutting, drilling, or installing
fasteners.
1. Insert PAC516 (A) into opening. (See Figure 2)
2. Using a stud sensor, locate and mark studs.
3. Center and level housing between marked studs.
4. Using housing as a template, draw pencil line completely
around housing.
NOTE: Housing is designed to fit between and directly against
two adjacent wall studs.
5. Using a measuring tool, measure the marked area and
compare to the dimensions below. If measurements match,
continue to Step 6. If not, adjust markings to match
dimensions below. (See Figure 1)
6. Cut drywall on outside edge of line and remove.
(A)
Figure 2
5
PAC516
Installation Instructions
WARNING: ELECTRICAL SHOCK HAZARD! CUTTING
OR DRILLING INTO ELECTRICAL WIRES OR CABLES
CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY!
ALWAYS make certain area behind mounting surfaces is free
of electrical wires and cables before cutting, drilling, or
installing fasteners.
DANGER: IMPROPER WIRING CAN LEAD TO DEATH
OR SEVERE PERSONAL INJURY! Grounding must be
installed by qualified personnel using a UL Recognized No.
12AWG Green and Yellow grounding wire connected to
grounding lug on mount.
2. Secure accessory box to studs by:
WOOD STUD:
1. Drill four 3/16" dia. pilot holes in studs at mounting
holes. (See Figure 3)
1
2. Install four M7 x 40mm Allen head connector screws
(F) into pilot holes using an M4 Allen head drill bit
(D). (See Figure 3)
2
STEEL STUD:
1. Drill four 3/16" dia. pilot holes in studs at mounting
holes. (See Figure 3)
2. Install four 1/4" countersunk finishing washers (B)
and four 1/4" x 2" Phillips flat head self drilling
screws (G) into pilot holes. (See Figure 3)
Typical
Grounding lug location
Figure 4
x 4
1
Installing Accessories
Accessories can be mounted directly to the PAC516 by using
the mounting screws provided and the mounting holes
integrated into the box.
To mount an accessory:
1. Identify area within accessory box where accessory is to be
mounted.
2. Align the mounting holes in accessory with mounting holes
in box.
3. Secure accessory to box using Phillips screwdriver and as
many 1/8-18 x 3/4" mounting screws (E) as required. (See
Figure 5)
4. Use the wire tie clips (C), as necessary, for cable
management. (See Figure 5)
(F) x 4
2
(B) x 4
(Steel Stud Only)
(G) x 4
(Steel Stud Only)
2
Figure 3
6
Installation Instructions
PAC516
(C)
3
(E) (8 provided)
Figure 5
7
PAC516
Installation Instructions
USA/International
Europe
A
P
F
A
P
F
6436 City West Parkway, Eden Prairie, MN 55344
800.582.6480 / 952.225.6000
877.894.6918 / 952.894.6918
Franklinstraat 14, 6003 DK Weert, Netherlands
+31 (0) 495 580 852
Chief Manufacturing, a products division
of Milestone AV Technologies
+31 (0) 495 580 845
Asia Pacific
A
Office No. 1 on 12/F, Shatin Galleria
18-24 Shan Mei Street
8807-002009 Rev01
¤2012 Milestone AV Technologies,
a Duchossois Group Company
09/12
Fotan, Shatin, Hong Kong
852 2145 4099
852 2145 4477
P
F
|