COMMERCIAL REFRIGERATOR AND FREEZER
OWNER'S MANUAL
Refrigerated Pizza Prep Units
Models: P1SRR-08S, P2SRR-16S, P3SRR-24S
Refrigerated Sandwich Prep Units
Models: S1BRR-06S, S2BRR-12S, SD3BRR-18S, M1P-2712, M2P-4818, M3P-7127
Undercounter Refrigerators & Freezers
Models: U1BRR-06S, U1BFF-06S, U2BRR-12S, U2BFF-12S
This manual contains important information regarding your new ColdTech
unit. Please read the manual thoroughly prior to equipment set-up,
operation and maintenance. Failure to comply with regular maintenance
guidlines outlined in this manual may void warranty. MUST READ!!!
INSTALLATION/ OPERATION
IMPORTANT!!! PLEASE READ BEFORE INSTALLATION
1) If the unit has recently been transported please let unit stand still for a minimum of 24 hours before
plugging it in.
2) Make sure that the unit drops down to desired temperature before loading the unit with product.
3) Make sure that there is proper ventilation around the unit in the area where it will operate.
4) Make sure all accessories are installed (i.e. shelves, shelf clips, casters) before plugging the unit in.
5) Please read through the Operation / Owners Manual in its entirety. Lack of maintenance or misuse of
the unit will VOID warranty. Please fill out the registration card and send it to the factory.
Pizza prep units
Sandwich Preps / Undercounters
CABINET LOCATION GUIDELINES
1) Install the unit on strong and leveled surfaces
-unit may make unpleasant noises if surface is uneven
-unit may malfunction if surface is uneven
3.0"
REAR
CLEARANCE
REQUIRED
NO
REAR
CLEARANCE
NECESSARY
2) Install the unit in an indoor, well-ventilated area
-unit performs more efficiently in a well-ventilated area
BACK
SIDE VIEW
FRONT
BACK
SIDE VIEW
FRONT
-for best performance, please maintain clearance of 3" on the back of the unit
-outdoor use may cause decreased efficiency and damage to the unit
3) Avoid installation in a high humidity and/or dusty area
-humidity could cause unit to rust and decrease effeciency of the unit
-dust collected on condenser coil will cause unit to malfunction. Clean the condenser at least
once a month with a brush or clean cloth
-malfunction due to dirty condenser will void warranty
4) Select a location away from heat and moisture-generating equipment
-high ambient temperatures will cause the compressor to overwork, leading to higher energy bills
and gradual breakdown of the unit
-malfuNction due to high ambient temperature will void warranty
ELECTRICAL
Please ensure that the required voltage of the compressor is being supplied at all times. Low or high
voltage can detrimentally affect the refrigeration unit and thereby void its warranty.
All units should be plugged into a grounded and properly-sized electrical outlet with appropriate
overcurrent protection. Please refer to the electrical requirements on the unit serial tag located inside the
unit. Please make sure that your unit has its own dedicated outlet. Do not use an extension cord.
-3-
TEMPERATURE CONTROLS
The temperature controls are factory-set to maintain an average temperature of 38 F in refrigerators and 0
F in freezers. To maintain a different temperature, simply adjust the control knob located inside the unit.
To decrease the temperature (colder), turn clockwise. To increase the temperature (warmer), turn
counter-clockwise - see diagram
6
CAUTION
7
5
Setting the temperature control to the
OFF
4
Temperatures range from
coldest setting may cause the evaporator
coil to freeze and ice up. This will eventually
result in a warmer cabinet temperature.
1
3
2
7 (coldest) to 1 (warmest).
TEMPERATURE
READING
LOADING PRODUCT
Shelves have been factory-installed for your convenience. Before loading shelves, please be sure that all
shelf clips are completely fastened in their correct locations. It is important that all shelves rest completely
level before stocking your cabinet with product.
In order to maintain correct air flow inside the unit, please be sure to leave two to four (2 to 4) inches of
space between the back wall and stored product. Blocking the evaporator fans will result in a warmer
cabinet temperature, and ultimately compressor failure.
DEFROST SYSTEMS
Refrigerator coils are kept below the freezing point (32 F). During compressor down-time, the evaporator
fan continues to circulate air through the evaporator coil. This air circulation raises the coil temperature
above the freezing point, melting any accumulated frost. Run-off water is drained into the evaporator pan
and evaporated. **Freezer coils are defrosted electrically.** Automatic defrost timers are built-in to the
refrigeration system and may not be adjusted. The defrost timers automatically initiate at pre-set intervals
and for a pre-determined duration.
**PLEASE NOTE: Excessive door openings should be avoided in order to maintain cabinet temperature
and to eliminate the possibility of coil freeze-up.**
LOADING FOOD PANS
Pizza prep units and sandwich prep units are designed to function with all pans in place, even if some
pans are to be left empty. For maximum food freshness, fill the pans only with an amount that can be
used in a specific usage period. During non-use, please close the insulated lid cover.
-4-
SAFETY / WARNING
Please pay close attention the the safety notices in this section. Disregarding
these notices may lead to serious injury and/or damage to the unit.
KEY
!
ATTENTION
UNPLUG CORD
PROPER GROUNDING REQUIRED
PROHIBITED
1) To minimize shock and fire hazards, be sure not to overload outlet. Please designate
one outlet for your unit.
!
2) Do not use extension cords.
3) Do not put your hands under the unit when the unit is required to be moved.
4) When the unit is not in use for a long period of time, please unplug the unit from the
outlet.
5) After unplugging the unit, wait at least 10 minutes before re-plugging it. Failure to do
so could cause damage to the compressor.
1) To minimize shock and fire hazards, please do not plug or unplug the cord with wet
hands.
2) During maintenance and cleaning, please unplug the unit.
1) To minimize shock and fire hazards, make sure that the unit is properly grounded.
1) Do not attempt to remove or repair any component unless instructed by factory.
2) Make sure that the unit is not resting on or against the electrical cord and plug.
3) To minimize personal injury, do not hang on the doors.
4) Do not store any flammable and explosive gas or liquids inside the unit.
5) Do not attempt to alter or tamper with the electrical cord.
6) Do not set the desired temperature out of the recommended temperature range:
(Ref: 32 F - 55 F
Fre: -15 F - 20 F)
-5-
REGULAR MAINTENANCE
CLEANING THE CONDENSER COIL
For efficient operation, it is important that the condenser surface be kept free of dust, dirt, and lint.
ColdTech recommends cleaning the condenser coil and fins at least once per month. Clean with a
commercial condenser coil cleaner, available from any kitchen equipment retailer. Brush the condenser
fins from top to bottom, not side to side. After cleaning, straighten any bent condenser fins with a fin
comb.
CLEANING THE FAN BLADES AND MOTOR
If necessary, clean the fan blades and motor with a soft cloth. If it is necessary to wash the fan blades,
cover the fan motor to prevent moisture damage.
CLEANING THE INTERIOR OF UNIT
When cleaning the cabinet interior, use a solvent of warm water and mild soap. Do not use steel wool,
caustic soap, abrasive cleaners, or bleach that may damage the stainless steel surface.
Wash door gaskets on a regular basis, preferably weekly. Simply remove door gasket from the frame of
the door, soak in warm water and soap for thirty (30) minutes, dry with soft cloth, and replace. Check door
gaskets for proper seal after they are replaced.
Periodically remove the shelves and pilasters from the unit and clean them with mild soap and warm
water. To remove the pilasters, first remove the shelves and shelf brackets. Then, simply lift the pilaster
up and out.
WARNING
Disconnect power cord before cleaning any parts of the unit.
TROUBLE SHOOTING
Before requesting any service on your ColdTech unit, please check the following points. Service calls
resulting from lack of maintenance or misuse is not covered under warranty and also may void warranty.
Please note that this guide serves only as a reference for solutions to common problems.
-6-
SYMPTOM
Compressor not running.
POSSIBLE CAUSE
Fuse blown or circuit breaker tripped.
CORRECTIVE ACTION
Replace fuse or reset circuit
breaker.
Power cord unplugged.
Thermostat set too high.
Plug in power cord.
Set thermostat to lower
temperature.
Cabinet in defrost cycle.
Wait for defrost cycle to finish.
Condensing unit runs for
long periods of time.
Excessive amount of warm product
placed in cabinet.
Prolonged door opening or door ajar.
Allow adequate time for
product to cool down.
Ensure doors are closed when
not in use. Avoid opening
doors for long periods of time.
Ensure gaskets are snapped in
completely. Remove gasket
and wash with soap and water.
Check condition of gasket and
replace if necessary.
Door gasket(s) not sealing properly.
Dirty condenser coil.
Evaporator coil iced over.
Clean the condenser coil.
Unplug unit and allow coil to
defrost. Make sure thermostat
is not set too cold. Ensure that
door gasket(s) are sealing
properly.
Cabinet temperature is
too warm.
Thermostat set too warm.
Blocking air flow.
Set thermostat to lower
temperature.
Re-arrange product to allow for
proper air flow. Make sure
there is at least four inches of
clearance from evaporator.
Allow adequate time for
product to cool down.
Excessive amount of warm product
placed in cabinet.
Fuse blown or circuit breaker tripped.
Replace fuse or reset circuit
breaker.
Dirty condenser coil.
Prolonged door opening or door ajar.
Clean the condenser coil.
Ensure doors are closed when
not in use. Avoid opening
doors for long periods of time.
(see above)
Evaporator coil iced over.
Loose part(s).
Cabinet is noisy.
Locate and tighten loose
part(s).
Tubing vibration.
Ensure tubing is free from
contact with other tubing or
components.
-7-
The New Symbol of Innovation™
MEMO
RETAIN THIS MANUAL FOR FUTURE REFERENCE
Please read the entire manual carefully before installation and operation. If certain recommended
procedures are not followed, warranty claims will be denied.
Notice: ColdTech reserves the right to make changes in design and specifications without prior notice.
MODEL #: _______________________________
SERIAL #: _______________________________
PURCHASE DATE #: _______________________
1575 Zephyr Ave., Hayward, CA 94544
(800) 314-4477 (510) 477-3400
f: (510) 477-3413
|